These filters screw onto the end of any standard syringe. 10ml syringes work nicely. The tip is perfect for fitting a needle onto, e.g. a 21 gauge needle fits very snug. This means you can directly filter a syringe full of your solution into another syringe, this secondary one obviously being empty and *unused / sterile!*
Jul 18, 2019 · Syringe Filter Size. Syringe filters range in diameter from 4 mm to 50 mm. The larger the diameter, the more particles can be captured on the filter surface before it begins to block, leading to back pressure and the force that must be applied to the syringe plunger to extract the purified material.
Water and acetonitrile were passed through polypropylene or PTFE syringe filters (as indicated in legend), then used 1:1 (v/v) to prepare the mobile phase for UHPLC. The system was run at 0.25 mL/min for 600 min with backpressure recorded every 50 min. DP represents total change in backpressure after 600 min.
Use these all-plastic disposable syringes with your Titan3, Target2, and Choice Basic syringe filters. Comprising a polypropylene barrel and polyethylene plunger, these syringes eliminate problems with rubber or synthetic plunger gaskets and requires no silicone or oil lubricant in the barrel. Choose from in 1, 3, 5, 10, 20, 30, and 50 mL sizes.
Feb 17, 2020 · The main options of syringe filters are below: PTFE Hydrophobic Syringe Filters 0.22 or 0.45um Hydrophobic PTFE (Polytetrafluoroethylene) syringe filters are suitable for gaseous and organic solutions, with excellent performance for high corrosive samples.
The PES syringe filters with GF pre-filter has excellent dirt-holding capacity, which makes a syringe filter a much larger throughput for some “hard to filter” sample. UNIFORM PORE SIZE - Sterile PES Syringe Filter with uniform pore size structure; wide pore size selection, retention of granule cell collection.
2-in-1 filters are a two-layered filter in a single housing with a built-in glass fiber pre-filter on the top layer and a membrane filter on the bottom layer. The coarse pre-filter removes the larger particulates that would plug the membrane filter. This type of filter is recommended for difficult-to-filter samples.
Sep 07, 2020 · 33mm diameter – for samples <250ml. 4. Select syringe fitting. Most syringe filters with come with the standardised Luer fitting – either Luer Lock or Luer Slip. Luer Slip – will fit on to any Luer fitting syringe. Simply ‘slip’ the filter onto the end of your syringe. It is quick to add and remove from the syringe.
Syringe Filters. Welchrom ® Syringe Filters are of good quality, well packaged, and offered at a fair and competitive price. The most commonly used types are available in all of the major membranes including Nylon, PTFE, PES, MCE and PVDF, which are supplied in 13 mm id, 25 mm id formats in virgin medical polypropylene housings.
ABLUO® Syringe Filters | GVSProperties. Increased throughput and speed of sample preparation. Lower hold-up volume due to an improved flow channel design and reduced spacing betwe
The pore size of your syringe filter is determined by the size of the particles you need to filter out of your aqueous solution. Syringe filters for aqueous solutions are available in these pore sizes: 0.05 µm, 0.10 µm, 0.22 µm, 0.45 µm, 0.70 µm, 0.80 µm, 1 µm, 3 µm, 5 µm, and 10 µm . As a guide, the finer the pore, the more pressure
Dec 07, 2020 · Syringe filters are made from a virgin polypropylene housing with a female luer lock inlet and a male slip luer outlet. To use syringe filters, the sample is loaded into a disposable luer syringe. The syringe is then attached to the female luer portion of the syringe filter by securely fastening with a twisting motion.
Syringe filters are sterilized by gamma irradiation, preventing the contamination risk that can result from ethylene oxide sterilization. They are individually blister packed to ensure sterility during storage and handling. Replacing a syringe filter midway through the process may lead to contamination, spills, and workflow disruption.
Whatman ® Puradisc ® syringe filters combine premium quality and economy and are ideal for quick, efficient filtration of samples up to 100 mL volumes. Whatman ® Puradisc ® Aqua syringe filters are specifically designed for filtration of environmental samples prior to COD and DOC analysis. The membranes used in these devices are prewashed prior to assembly to reduce the organic carbon level.
Syringe filters are generally a necessary laboratory supply that may be applied over a broad spectrum of research laboratory procedures. They tend to be generally utilized in the preparation of aqueous and organic solutions, in which it is important to have quick and efficient filtration. Syringe filters will also be needed for the biotech
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack