Pore Sizes and Pore Volumes. The filter size depends highly on the filtration volume. For small volumes (< 1 ml), syringe filters with a diameter of 3 mm are usually for medium volumes (1-10 ml), 15 mm and for large volumes (> 10 ml) 25 mm. Common pore sizes for UHPLC and HPLC columns with small particle sizes (< 3 µm) are 0.2 and for columns with larger particle sizes (> 3.5 µm) 0.45 µm
Acrodisc White Blood Cell (WBC) syringe filter, designed specifically to capture and recover Leukocytes while separating red blood cells and platelets, thereby providing scientists with a simple and efficient method to isolate cells needed for use in a variety of research applications or prepare leukocyte depleted blood for analysis
A syringe filter (or wheel filter) is a single-use, membrane-based device used for the removal of particulate impurities from small (≤ 100 mL) liquid samples (Figure 1). Selected based upon the desired end application, disposable syringe filters are commonly used in labs for fast and efficient filtering, material purification, or even sterilization.
The pore size of your syringe filter is determined by the size of the particles you need to filter out of your aqueous solution. Syringe filters for aqueous solutions are available in these pore sizes: 0.05 µm, 0.10 µm, 0.22 µm, 0.45 µm, 0.70 µm, 0.80 µm, 1 µm, 3 µm, 5 µm, and 10 µm . As a guide, the finer the pore, the more pressure
Water and acetonitrile were passed through polypropylene or PTFE syringe filters (as indicated in legend), then used 1:1 (v/v) to prepare the mobile phase for UHPLC. The system was run at 0.25 mL/min for 600 min with backpressure recorded every 50 min. DP represents total change in backpressure after 600 min.
Sterile Syringe Filters. Sterile Diamond® PureFlow™ syringe filters satisfy requirements of life science applications for sterilization of solutions or clarification of biological fluids. Sterile filters include a polypropylene microfiber pre-filter layer to improve filtration of particulate-laden fluids that are difficult to filter with
Sterile filtration, clarification, and particle removal. Minisart ® NML Syringe Filters provide the optimal method for clarification and sterilization of liquids, robustly removing bacteria and particles, without any impact on product quality or loss of target molecule. Superior filter areas up to 6.2 cm 2. 0.1µm to 5µm pore sizes.
Jan 25, 2022 · Yellow nylon syringe filters The NYL filters with a 0.22µm pore size have a water flow of 23ml/min/cm 2 and a bubble point of 340kPa. The 0.45µm pore size filters have a water flow of 46ml/min/cm 2 and a bubble point of 220kPa. Mixed cellulose esters (MCE) filters
Intro. There are so many solvents and syringe filter/membrane materials that it can be tough to remember which combinations are safe and which are corrosive. These tables show five common syringe filter materials -- Cellulose Acetate (CA), Nylon, PES, PTFE, and PVDF -- and their compatibilities with 75 common solvents.
Syringe filters (or wheel filters) are a single-use filter cartridge locate at the end of a syringe. Syringe filters can have luer lock fittings for a secure fit to the syringe. Choose from our wide assortment of filters to suit your application. Syringe filters come in a variety of membrane types. When selecting a syringe filter, be
These syringe filters are recommended for "pharmaceutical" grade HPLC Sample Prep & Dissolution Testing when GLP and GMP are required. Manufactured with proprietary and various membrane types in 25mm, 13mm or 4mm polypropylene housings. These color coded, syringe filters are also made for laboratories that require consistent, high performance
Syringe filters are attached to the end of a syringe to remove particles from a sample prior to analysis. Filtering liquids, the single-use devices force liquids through the filter either when fluids are initially drawn or delivered. Circular shaped in diameters that fit common syringe sizes, the cartridges remove fragments that would otherwise
Syringe filters with cellulose acetate or polyethersulfone membranes are ideal for sterile filtration of buffers, tissue culture media or additives, and other biologicals. The polyethersulfone membrane offers high flow rates. Nonsterile syringe filters are excellent for HPLC applications. Each filter has a female Luer-lock inlet and a male slip
Corning® 50 mm Diameter Syringe Filters, 0.2 µm Pore PTFE Membrane, Sterile, Individually Packaged, 12/Case 1 / Pk 12 / Cs Corning® $158.98: per case: Add to cart
CHROMAFIL® MULTI 96 filter plates. Disposable syringes, PP, with luer tip. HPLC syringe filter ProFill, PTFE. HPLC syringe filter ProFill, RC / PA. LLG Syringe Filter CA, Cellulose acetate. LLG Syringe Filter GF, Glass-fibre. LLG Syringe Filter NY, Nylon/Polyamide. LLG Syringe Filter PE, Polyethylene. LLG Syringe Filter PES, Polyethersulfone.
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack