Sep 16, 2022 · As the name suggests, syringe filters consist of a plastic housing and a membrane. The liquid is forced to pass through a membrane filter of a particular pore size, which depends on the size of impurities that you are dealing with in your specimens. The filter prevents the passage of contaminants and there, is a perfect sample for your experiments!
Choosing the proper filter size is crucial to avoid rupturing the syringe filter’s housing. As a guide, if the volume of fluid to filter is: 5 to 1.0 ml, then use a 4mm syringe filter; 2-10 ml, then use a 13mm syringe filter; 10-100 ml (or up to 200 ml with a prefilter), then use a 25mm syringe filter; 2-5 L, then use a 50mm syringe filter.
Phenex syringe filters are designed for efficient and rapid filtration of almost any solution prior to analysis, and are optimized for superior flow rates and high-throughput. Phenex offers a wide variety of membranes ideal for any application. High quality filtration product Increased column lifetime Less system downtime
Syringe Filters: Take the Guesswork Out of Selection Syringe Filters: Take the Guesswork Out of Selection On-Demand Webinar What Will I Learn Filtration is a critical part of analytical sample prep, yet choosing the right syringe filter for your specific application can be challenging. Register to learn how to simplify the process.
Load the sample into the syringe. Fix the filter securely with a twisting motion. With a Luer Slip syringe, this is about a quarter turn when the filter is pushed in. If the syringe has a luer lock, attach it firmly but do not overtighten. Hold the assembled syringe and filter vertically to evenly wet the membrane (this promotes high flow rates).
Dec 13, 2022 · There are three main types of syringe filters: hydrophobic, hydrophilic, and membrane. Hydrophobic filters are made of a material that repels water, while hydrophilic filters are made of a material that attracts water. Membrane filters are made of a semipermeable material that allows only certain molecules to pass through.
Feb 17, 2020 · A syringe filter (sometimes called a wheel filter for its wheel-like shape) is a single-use membrane based filter cartridge, to be attached with a syringe to remove impurities in liquid solutions. This pre-filtration step is vital in preventing damage to instruments (e.g. liquid chromatography, ICP, etc.).
Syringe filters are available in a range of sizes with different effective filtration areas (EFA). EFA is the filter area that is available for filtration. For a given membrane, the larger the filter area, the higher the flow rate and greater the throughput. Throughput is the amount of fluid able to pass through a filter prior to plugging.
30mm Hydrophilic PTFE Filter 0.2 µm 100pcs/Pack (Non-Sterile) $ 75.00 30mm Mixed Cellulose Ester Filter 0.22 µm 100pcs/Pack (Non-Sterile) $ 75.00 Welcome to SyringeFilter.com SyringeFilter.com distributes high quality syringe filters to the scientific community at competitive prices. We provide one-time or recurring shipments.
Dec 15, 2022 · Syringe filters are devices that are used to remove particulate matter from a liquid sample prior to analysis. They are typically made of a hydrophilic membrane that is placed over a filter support, and the sample is forced through the membrane using a syringe. The particulate matter is retained on the filter, while the filtrate passes through.
May 19, 2022 · Syringe Filter Media Selection Guide 1. Cellulose Acetate (CA) The hydrophilic filter membrane has uniform pore size, high porosity, low resistance, a fast filtration rate, and minimal adsorption. They are mainly used to filter out particles and bacteria in biological samples and water-soluble samples. 2. Nylon (NY)
Mar 27, 2022 · So, in analysis, non-sterile syringe filters can help you get the most out of your equipment. 1. UHPLC, 2. LC-MS. 3. Ion chromatography. 4. Dissolution testing. In Which Cases Do You Use a Sterile Syringe Filter in General? Use a sterile syringe filter for sterilizing liquids or purifying sterilized solutions.
Whatman ® Uniflo syringe filters are disposable filtration devices for removing solids from liquid samples prior to analyses such as HPLC and UV/Vis spectrophotometry. They are available in variety of membrane choices with 0.2 μm or 0.45 μm pore sizes, feature a polypropylene overmold housing, and include both sterile and non-sterile options.
Our 25 mm syringe filters use the identical materials of construction as our entire capsule filter portfolio to ensure streamlined scaling without requalification or revalidation concerns. From our syringe filters with 4 cm 2 of surface area to our 50″ UltraCap ® H.D. filters with up to 3.6 m 2 of surface area, the only thing that changes as
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack