Syringe Filters. Syringe filters are single-use, membrane-based devices used for the removal of particulate impurities from liquid and gas samples prior to analysis by methods such as HPLC, ion chromatography, gas chromatography, ICP, and dissolution testing. Proper filtration of samples improves the quality and consistency of analytical
Non-Sterile: 30mm Syringe Filters; Non-Sterile: 25mm Syringe Filters; Non-Sterile: 13mm Syringe Filters; Non-Sterile: 50mm In-Line Filters; Non-Sterile: Cellulose Acetate; Non-Sterile: Hydrophilic PTFE; Non-Sterile: Hydrophobic PTFE; Non-Sterile: Mixed Cellulose Ester; Non-Sterile: Nylon; Non-Sterile: Polyethersulfone; Non-Sterile: Polypropylene; Non-Sterile: PVDF
Product List Non-Aqueous Syringe Filters Product Code C101 C102 C103 C104 C2006S2 C2006S1 Pore Size 0.1 μm 0.22 μm 0.45 μm 1.2 μm 0.1 μm 0.45 μm Membrane PTFE (Hydrophobic) PVDF (Hydrophobic) Filter Diameter 13 mm Filtration Area >1.3 cm2 Retained Fluid <100 μl Pack Size 100 filters Package Type Low dust polyethylene box *If you require
HIXWER Syringe filters are developed under production processes with strict quality controls, assuring a safe and reliable product for your laboratory analysis. They are used to filter small volumes of aqueous solutions, aggressive gases and air in hydrophobic vents or to perform sterile dosages.
Syringe Filter Selection Guide. Use our quick, interactive syringe filter selection guide to find out what filter is best suited to your analysis. In a few clicks you can submit your recommendations and we will send you a free, personalised sample pack. While you are here you should also look at our filtration products page.
Nylon Syringe Filter,25mm,0.45µm, Non-Steriled: Part Number:SFNY025045N: Lot Number:100609009
Syringe Filters. Welchrom ® Syringe Filters are of good quality, well packaged, and offered at a fair and competitive price. The most commonly used types are available in all of the major membranes including Nylon, PTFE, PES, MCE and PVDF, which are supplied in 13 mm id, 25 mm id formats in virgin medical polypropylene housings.
Filters are molded in the polypropylene housings, providing a reliable seal without the use of adhesives Female luer-lock inlet and male luer slip outlet Color coded by membrane type for easy identification, and membrane material and pore size are printed on the housing Available individually packed in peel-to-open paper/plastic blister packs Also available bulk packed in PVDF, PES, PTFE, and
1. Filter housing material is made of high quality sanitary polypropylene material. 2. The precise design of syringe filter structure ensures smooth filtration, rationalized internal space, and very low residual rate, which reduces sample waste. 3. The edge of the syringe filter is provided with threads to play a non-slip effect.
Syringe Filters. Diamond® PureFlow™ syringe filters from Globe Scientific provide high-quality, cost-effective filtration systems that improve the reliability of experimental results and decrease instrument downtime. All Diamond PureFlow syringe filters are constructed of a durable polypropylene housing secured around the membrane with a
Tisch Scientific offers an extensive selection of proven, yet affordable syringe filters that are in stock and ready to ship today. Selected for their durability, material quality and performance characteristics, our syringe filters deliver accurate, measurable results at a fraction of the cost.
Feb 17, 2020 · PVDF Hydrophilic Syringe Filters 0.22um or 0.45um . Hydrophilic PVDF (Polyvinylidene Fluoride) is an optimal choice for protein-based samples with high non-specific binding, HPLC (High Performance Liquid Chromatography) and UHPLC (Ultra HPLC).
Mar 27, 2022 · Step – Now, Select a Proper Pore Size. For research and medical purposes, 0.2/0.22 μ and 0.45 μ syringe filters are the most often used pore sizes. The particle size determines the pore size you use. For example, use a syringe filter of 0.2-micron pore size to filter out particles larger than 0.2 microns in diameter.
Jan 25, 2022 · Orange cellulose acetate syringe filters The CA filters with a 0.22µm pore size have a water flow of 23ml/min/cm 2 and a bubble point of 340kPa. The 0.45µm pore size filters have a water flow of 46ml/min/cm 2 and a bubble point of 220kPa. Nylon (NYL) filters
With low extractables and low analyte-binding membranes, Millex® syringe filters are the most convenient, highest-quality syringe filters for sensitive instrumental analyses, including gas, liquid, and ion chromatography. Wide chemical compatibility enables their use with virtually any sample composition. Request your FREE Millex® filter sample!
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack