Syringe Filters for Sterile Filtration | Minisart® | Sartorius Sterile filtration, clarification, and particle removal. Minisart ® NML Syringe Filters provide the optimal method for clarification a...
Share With:
Description
Inquiry
Description:

Syringe Filters for Sterile Filtration | Minisart® | Sartorius

Sterile filtration, clarification, and particle removal. Minisart ® NML Syringe Filters provide the optimal method for clarification and sterilization of liquids, robustly removing bacteria and particles, without any impact on product quality or loss of target molecule. Superior filter areas up to 6.2 cm 2. 0.1µm to 5µm pore sizes.

Syringe Filters - Pall Corporation

For example, Pall supply both a traditional ring molded 25 mm syringe filter and the Premium Syringe Filter (PSF) 25 mm syringe filter. The PSF syringe filter has a much larger effective filtration area compared with the older traditional model, 3.9 cm 2 compared to 2.8 cm 2. Therefore, this gives the PSF syringe filter a much improved throughput and flow rate.

Syringe filters - which one do I need? - The Laboratory People

Jan 25, 2022 · These filters are available with two different pore sizes, – 0.22 and 0.45µm, and are available in three different syringe filter sizes – 13, 25 and 33mm. Green mixed cellulose ester syringe filters. The MCE filters with a 0.22µm pore size have a water flow of 8.5ml/min/cm 2 and a bubble point of 350kPa.

6 ways to know the syringe filter better - Meticlab

Jul 18, 2019 · A syringe filter generally consists of a plastic housing with a membrane which serves as a filter. The fluid to be purified may be cleaned by drawing it up the syringe through the filter, or by forcing the unfiltered fluid out, through the filter. In scientific applications, the most common sizes available are 0.2 or 0.22 µm and 0.45 µm pores.

syringe filter with key-Analytical Testing Vials

CellPro™ Syringe Filters• Ultrasonic Welded • 25mm Filter Diameter for volumes between 10-100mL• Filter Inlet: Luer Lock Female, Filter Outlet: Luer Male • Maximum operating press Tel: 8618057059123

How to Select a Syringe Filter and How to Use it? (2020 Guide)

Feb 17, 2020 · PVDF Hydrophilic Syringe Filters 0.22um or 0.45um . Hydrophilic PVDF (Polyvinylidene Fluoride) is an optimal choice for protein-based samples with high non-specific binding, HPLC (High Performance Liquid Chromatography) and UHPLC (Ultra HPLC).

How to Choose a Syringe Filter? - Size, Material, and Simple

Mar 27, 2022 · Step – Now, Select a Proper Pore Size. For research and medical purposes, 0.2/0.22 μ and 0.45 μ syringe filters are the most often used pore sizes. The particle size determines the pore size you use. For example, use a syringe filter of 0.2-micron pore size to filter out particles larger than 0.2 microns in diameter.

Syringe Filters - Sigma-Aldrich

MILLEX ® -LCR Syringe Filter, 0.45 μm Hydrophilic PTFE, 33 mm, Nonsterile 0.45 μm pore size SLGVV255F Millex-GV Filter, 0.22 µm, A 25 mm diameter sterile syringe filter with a 0.22 µm pore size hydrophilic PVDF membrane. Comes in a pack of 50. 0.22 μm pore size SLHN033

How to choose the correct syringe filter - Biomall Blog

Oct 02, 2019 · Filter Diameter: Syringe filter diameter depends upon the volume of the sample to be filtered. If the volume of the aqueous sample is Higher, the filter should be with a larger diameter. Syringe filters are available in a variety of diameters including 4mm, 13mm, 17mm, 20mm, 25mm, 30mm, and 33mm. For smaller volume samples (approximately 1 ml

Syringe Filters - Sigma-Aldrich

A syringe filter (or wheel filter) is a single-use, membrane-based device used for the removal of particulate impurities from small (≤ 100 mL) liquid samples ( Figure 1 ). Selected based upon the desired end application, disposable syringe filters are commonly used in labs for fast and efficient filtering, material purification, or even

High Quality Specialty Syringe Filters | I.W. Tremont

Syringe Filter Capabilities. Beyond the extensive product selection found within our standard syringe filter list, we offer OEM capabilities for engineering, molding and insertion of many additional membrane and membrane/pre-filter options.

Qmx Laboratories - Syringe Filters

Klarity 25mm, 13mm and 4mm syringe filters are certified for conformance to key tests including bubble point, burst pressure, filter Integrity, water flow rate and UV extractables.

Syringe Filters | Corning

Corning® 50 mm Diameter Syringe Filters, 0.2 µm Pore PTFE Membrane, Sterile, Individually Packaged, 12/Case 1 / Pk 12 / Cs Corning® $158.98: per case: Add to cart

Syringe Filters - Laboratory Notes

Syringe filters are disposable devices that are equipped with filter paper. These filter papers are available in different pore sizes, ranging from 0.2 µm – 0.45 µm. These filter devices are used to remove particular materials from the solution.

Inquiry
Please feel free to submit your inquiry information to us. We will contact with you as soon as possible.
Name:
Company:
Email:*
Phone:
Inquiry:*