Filters are molded in the polypropylene housings, providing a reliable seal without the use of adhesives Female luer-lock inlet and male luer slip outlet Color coded by membrane type for easy identification, and membrane material and pore size are printed on the housing Available individually packed in peel-to-open paper/plastic blister packs Also available bulk packed in PVDF, PES, PTFE, and
Whatman 6888-2527 GD/X 25 mm Syringe Filter, glass microfiber GF/D filtration medium, 2.7 um (150 pcs) Regular Price $539.90 Price $468.86. Add to Cart. Whatman Puradisc FP 30 mm Cellulose Acetate Syringe Filter, 1.2 µm, Sterile, 50 Pack, 10462261. Regular Price $114.27 Price $99.24.
Syringe filters are sterilized by gamma irradiation, preventing the contamination risk that can result from ethylene oxide sterilization. They are individually blister packed to ensure sterility during storage and handling. Replacing a syringe filter midway through the process may lead to contamination, spills, and workflow disruption.
Syringe filters are single use, self contained, filtration devices that are typically used to remove contaminating particulate from liquids or gasses. When selecting the correct syringe filter for an application there are a number of factors to consider, these include: Filter and housing materials. Pore size. Effective filtration area.
Syringe filters (or wheel filters) are a single-use filter cartridge locate at the end of a syringe. Syringe filters can have luer lock fittings for a secure fit to the syringe. Choose from our wide assortment of filters to suit your application. Syringe filters come in a variety of membrane types. When selecting a syringe filter, be
PTFE Syringe Filters. PTFE syringe filters are hydrophobic and chemically resistant to all solvents, acids, and bases. PTFE does not impart any extractables to the filtrate. It's an ideal material for transducer protectors because it blocks water vapor. PTFE is ideal for filtering and de-gassing chromatography solvents.
Syringe filters with cellulose acetate or polyethersulfone membranes are ideal for sterile filtration of buffers, tissue culture media or additives, and other biologicals. The polyethersulfone membrane offers high flow rates. Nonsterile syringe filters are excellent for HPLC applications. Each filter has a female Luer-lock inlet and a male slip
Syringe Filter EMD Millipore Millex-GV 0.22 µm, Natural, Hydrophilic Polyvinylidene Fluoride (PVDF), HDPE, 4 X 19.7 mm, Sterile, 0.1 cm² Filtration Area, 1 mL Volume, 10 µL Hold-up Volume, Hydrophilic Wettability, Female Luer-Lok/Male Luer Slip, Stepped Connections, GV Filter Code, Female Luer-Lok® Fitting Inlet, Male Luer Slip Fitting Outlet Stepped, 14 bar (200 psi) Maximum Inlet
Syringe Filters by Pore Size 0.45 μm and 0.2/0.22 μm are the two most frequently used membrane pore sizes for research and medical applications. 0.45 μm membranes are typically used for general filtration and particle removal applications.
Syringe Filters Solvent Compatibility Chart 1 Protect any analytical system. 2 Extend LC column lifetime. 3 Achieve more reproducible analyses. 4 Variety of membranes, porosities, and diameters available. 5 Luer lock inlet provides strong, leak-tight syringe connection to withstand filtration pressure.
Feb 17, 2020 · The most commonly used syringe filter pore sizes are 0.2/0.22 um and 0.45 um syringe filters, for research and medical applications. The pore size to be used is usually determined by the particle size to be eliminated.
Non-Sterile: 30mm Syringe Filters. Non-Sterile: 25mm Syringe Filters. Non-Sterile: 13mm Syringe Filters. Non-Sterile: 50mm In-Line Filters. Non-Sterile: Cellulose Acetate. Non-Sterile: Hydrophilic PTFE. Non-Sterile: Hydrophobic PTFE. Non-Sterile: Mixed Cellulose Ester. Non-Sterile: Nylon.
It would be expected that syringe filters containing absolute rated membrane media would be approximately equivalent regardless of supplier for filters that have the same size, same membrane material and same pore size rating. This is not the case for syringe filters containing nominally rated media such as glass fiber or nonwoven polypropylene.
Dec 07, 2020 · Chrom Tech’s 30mm syringe filters can be chosen for filter samples less than 200mL. 13mm syringe filters are a popular choice for most chromatography methods and typically chosen when sample volume is less than 10mL. Syringe Filter Pore Size. Two porosities of membranes are available for our syringe filters, 0.45 micron and 0.2 micron.
Syringe Filter Selection Guide. Use our quick, interactive syringe filter selection guide to find out what filter is best suited to your analysis. In a few clicks you can submit your recommendations and we will send you a free, personalised sample pack. While you are here you should also look at our filtration products page.
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack