A variety of membranes are available to meet your needs: Polyethersulfone (PES) – low protein binding and faster flow rates; surfactant-free cellulose acetate (SFCA) – lowest protein binding; polytetrafluorethylene (PTFE) – chemical resistance; regenerated cellulose (RC) – best choice for DMSO compatibility; Nylon (NY) – hydrophilic, surfactant-free, and lowest extractable. 100%
Non-Sterile: 25mm Syringe Filters. Non-Sterile: 13mm Syringe Filters. Non-Sterile: 50mm In-Line Filters. Non-Sterile: Cellulose Acetate. Non-Sterile: Hydrophilic PTFE. Non-Sterile: Hydrophobic PTFE. Non-Sterile: Mixed Cellulose Ester. Non-Sterile: Nylon.
Sterile Syringe Filters. Sterile Diamond® PureFlow™ syringe filters satisfy requirements of life science applications for sterilization of solutions or clarification of biological fluids. Sterile filters include a polypropylene microfiber pre-filter layer to improve filtration of particulate-laden fluids that are difficult to filter with
Make sure that the Luer-Lok™ is matching with the syringe to prevent the filter from coming off during the filtration. Filtration. Direct the SiliCycle Syringe Filter tip into the collection vessel and apply gentle pressure onto the syringe plunger. Push the liquid sample and the air volume through the SiliCycle Syringe Filter to maximize
Key Features: Ozone resistant materials, kynar and ABS Luer lock connections for easy connection to syringe and other accessories 0.22u filter, for filtering out small particulates Product Description: The syringe filter is for filtering out potential particulates from the gas. It is an ozone resistant filter, using k
Water and acetonitrile were passed through polypropylene or PTFE syringe filters (as indicated in legend), then used 1:1 (v/v) to prepare the mobile phase for UHPLC. The system was run at 0.25 mL/min for 600 min with backpressure recorded every 50 min. DP represents total change in backpressure after 600 min.
Syringe Filter Selection Guide. Use our quick, interactive syringe filter selection guide to find out what filter is best suited to your analysis. In a few clicks you can submit your recommendations and we will send you a free, personalised sample pack. While you are here you should also look at our filtration products page.
0.22 micron 0.45 micron syringe filters nylon Nylon PTFE PES GF glass fiber 13mm 30mm 25mm PVDF Polyvinylidene Fluoride Cellulose Acetate Filter syringe filter
Minisart ® NML Syringe Filters provide the optimal method for clarification and sterilization of liquids, robustly removing bacteria and particles, without any impact on product quality or loss of target molecule. Superior filter areas up to 6.2 cm 2. 0.1µm to 5µm pore sizes. Low adsorption characteristics.
Hawach Scientific - Syringe Filter, sterile, 25mm, 0.22um, 100pk. This syringe filter has a low protein binding membrane to maximize recovery of critical components. Gamma radiated, individually blister packaged. Attaches to luer tip of syringe: 0.2 u filter screen, 25mm disc diameter. View how to use a Syringe Filter
Syringe filters are attached to the end of a syringe to remove particles from a sample prior to analysis. Filtering liquids, the single-use devices force liquids through the filter either when fluids are initially drawn or delivered. Circular shaped in diameters that fit common syringe sizes, the cartridges remove fragments that would otherwise
The filter size depends highly on the filtration volume. For small volumes (< 1 ml), syringe filters with a diameter of 3 mm are used for medium volumes (1-10 ml), 15 mm and for large volumes (> 10 ml) 25 mm. Common pore sizes for UHPLC and HPLC columns with small particle sizes (< 3 µm) are 0.2 and for columns with larger particle sizes (> 3
All Captiva premium syringe filters are shipped with an HPLC or LC/MS certificate that guarantees low levels of observed extractables. Excellent flow rates and maximum sample loading capacities. Every syringe filter is constructed with the highest-grade virgin polypropylene or MBS housing. Securely welded to prevent bursting and ensure sample
Polypropylene, nylon, and PTFE membranes are ideal for sample preparation and small volume chemical filtration.Syringe filters are attached to the end of a syringe to remove particles from a sample prior to analysis. Filtering liquids, the single-use devices force liquids through the filter either when fluids are initially drawn or delivered. Circular shaped in diameters that fit common
Feb 17, 2020 · PVDF Hydrophilic Syringe Filters 0.22um or 0.45um . Hydrophilic PVDF (Polyvinylidene Fluoride) is an optimal choice for protein-based samples with high non-specific binding, HPLC (High Performance Liquid Chromatography) and UHPLC (Ultra HPLC).
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack