Pall Acrodisc® Sterile Syringe Filters with Supor® Membrane, Pall Laboratory. Supplier: Pall Laboratory. Description: These sterile syringes filters with Supor membrane are ideal for cell culture, biological research, and the filtration of other aqueous solutions. Certificates.
The prefilter contains a high-efficiency borosilicate glass filtration stack that will retain fine particles down to 0.7 μm, allowing difficult sample filtration with less hand force. It reduces the need for multiple syringe filters by processing three to seven times more sample volume than syringe filters without prefilters.
Syringe Filters MilliporeSigma™ Millex™-GP Sterile Syringe Filter Units with PES Membrane, 0.22 μm (Research Use Only) Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions
Product Support. Cytiva's Whatman GD/X sterile syringe filter is designed to support filtration of viscous, hard-to-filter samples with high solids content. Reduces need for multiple syringe filters by processing three to seven times more sample volume than syringe filters without prefilters. Female luer lock for leak-free connections.
Hold the syringe with the filter pointing up and “top off” by pushing a few drops through the filter. Place the filter tip over the collection container and push the sample through a syringe filter by applying gentle positive pressure. To purge the syringe filter and maximize sample throughput, remove the filter from the syringe and draw air into the syringe. Then reattach the filter and push the plunger to force some of the air through the filter.
Filters Syringe Filters. Available with either cellulose acetate or PES membrane. Sterile membranes with 0,2 µm pore size are ideal for sterile filtration applications, whilst those with 0,45 µm pore size can be used for clarifications. These sterile syringe filters are gamma irradiated to prevent cytotoxic residues caused by alternative
Syringe Filters. Syringe filters with high burst strength for assured performance. Manufactured to ISO 9002 and GMP standard and 100% integrity tested. Syringe filter sizes include 4, 15, 25, or 26 mm diameter to handle volumes ranging from 0.5 to 100 ml. The 50 mm diameter PTFE syringe filter are ideal for protecting the vacuum line and pump.
Syringeless and Syringe Filters. Syringe filters and membranes for the removal of interfering materials and fine particles prior to injection; includes filters both with and without syringes; suitable for both aqueous and aqueous-organic samples; often constructed from PVDF or PTFE.
It would be expected that syringe filters containing absolute rated membrane media would be approximately equivalent regardless of supplier for filters that have the same size, same membrane material and same pore size rating. This is not the case for syringe filters containing nominally rated media such as glass fiber or nonwoven polypropylene.
Whatman GD/X Syringe Filters are high-viscosity filters that incorporate a prefilter to enable filtration of viscous, dense or otherwise hard-to-filter material with high solids content as in environmental and food analysis samples.Syringe filters are attached to the end of a syringe to remove particles from a sample prior to analysis. Filtering liquids, the single-use devices force liquids
Polypropylene syringe filters are the optimal choice for analytical sample preparation. Pall’s polypropylene non-sterile syringe filter housing is chemically resistant to harsh solvents, is low in extractables and low in API and biomolecular compound adsorption. Chemical compatibility is a critical consideration when selecting a syringe filter.
These syringe filters are recommended for "pharmaceutical" grade HPLC Sample Prep & Dissolution Testing when GLP and GMP are required. Manufactured with proprietary and various membrane types in 25mm, 13mm or 4mm polypropylene housings. These color coded, syringe filters are also made for laboratories that require consistent, high performance
Sterile filtration, clarification, and particle removal. Minisart ® NML Syringe Filters provide the optimal method for clarification and sterilization of liquids, robustly removing bacteria and particles, without any impact on product quality or loss of target molecule. Superior filter areas up to 6.2 cm 2. 0.1µm to 5µm pore sizes.
0.22 micron 0.45 micron syringe filters nylon Nylon PTFE PES GF glass fiber 13mm 30mm 25mm PVDF Polyvinylidene Fluoride Cellulose Acetate Filter syringe filter $ 0.00 'Item' was added to your cart.
Feb 17, 2020 · A syringe filter (sometimes called a wheel filter for its wheel-like shape) is a single-use membrane based filter cartridge, to be attached with a syringe to remove impurities in liquid solutions. This pre-filtration step is vital in preventing damage to instruments (e.g. liquid chromatography, ICP, etc.).
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack