The labForce Solvent Filtration vacuum filters are a safe alternative to syringe filtration as well, using vacuum to filter a liter or more without the need for manual syringe work. The simple funnel design eliminates the risk of Related Products: Hplc Solvent Filter Compare this item Nonsterile MCE Syringe Filters Thomas®
Millex® Syringe filters set the standard for reliable small volume filtration (1 mL to 200 mL). Available in 4, 13, 25, 33, and 50 mm diameters. Minimal hold-up volume for less sample loss o f small volumes and are ideal for solutions such as antibiotics and tissue culture additives. Their unsurpassed quality and consistency of results has led
The pore size of your syringe filter is determined by the size of the particles you need to filter out of your aqueous solution. Syringe filters for aqueous solutions are available in these pore sizes: 0.05 µm, 0.10 µm, 0.22 µm, 0.45 µm, 0.70 µm, 0.80 µm, 1 µm, 3 µm, 5 µm, and 10 µm . As a guide, the finer the pore, the more pressure
Syringe filters are sterilized by gamma irradiation, preventing the contamination risk that can result from ethylene oxide sterilization. They are individually blister packed to ensure sterility during storage and handling. Replacing a syringe filter midway through the process may lead to contamination, spills, and workflow disruption.
Syringe filters are single use, self contained, filtration devices that are typically used to remove contaminating particulate from liquids or gasses. When selecting the correct syringe filter for an application there are a number of factors to consider, these include: Filter and housing materials. Pore size. Effective filtration area.
Use these all-plastic disposable syringes with your Titan3, Target2, and Choice Basic syringe filters. Comprising a polypropylene barrel and polyethylene plunger, these syringes eliminate problems with rubber or synthetic plunger gaskets and requires no silicone or oil lubricant in the barrel. Choose from in 1, 3, 5, 10, 20, 30, and 50 mL sizes.
Syringe filters are attached to the end of a syringe to remove particles from a sample prior to analysis. Filtering liquids, the single-use devices force liquids through the filter either when fluids are initially drawn or delivered. Circular shaped in diameters that fit common syringe sizes, the cartridges remove fragments that would otherwise
Water and acetonitrile were passed through polypropylene or PTFE syringe filters (as indicated in legend), then used 1:1 (v/v) to prepare the mobile phase for UHPLC. The system was run at 0.25 mL/min for 600 min with backpressure recorded every 50 min. DP represents total change in backpressure after 600 min.
These syringe filters are available with many different membranes, in both sterile and non-sterile varieties, and with or without pre-filters. You can also find expired sterile syringe filters at discount prices in our Clearance Section. *NOTE: Due to high demand, 13 and 25 mm diameter syringe filters are experiencing increased lead times
Hold the syringe with the filter pointing up and “top off” by pushing a few drops through the filter. Place the filter tip over the collection container and push the sample through a syringe filter by applying gentle positive pressure. To purge the syringe filter and maximize sample throughput, remove the filter from the syringe and draw air into the syringe. Then reattach the filter and push the plunger to force some of the air through the filter.
Our experienced scientists and professionals are ready to assist you with any technical support questions. Every question is considered a good question and we will work with you on a solution as fast as possible. Call us: 8:30AM – 6:00PM EST 1-732-380-8900 and hit 0#. Fax to us: 1-910-769-9435. Email Technical Support.
Syringeless and Syringe Filters. Syringe filters and membranes for the removal of interfering materials and fine particles prior to injection; includes filters both with and without syringes; suitable for both aqueous and aqueous-organic samples; often constructed from PVDF or PTFE.
Minisart ® NML Syringe Filters provide the optimal method for clarification and sterilization of liquids, robustly removing bacteria and particles, without any impact on product quality or loss of target molecule. Superior filter areas up to 6.2 cm 2. 0.1µm to 5µm pore sizes. Low adsorption characteristics.
There are several methods an analyst can use to process difficult to filter samples. By using a syringe filter with an integrated prefilter, throughput can be increased by 29% without the added time and risk of using dilution or centrifugation techniques.
5335.00 SEK. 13. Cytiva Whatman™ GD/X Sterile PES Syringe Filters. Processes three to seven times more sample volume than filters without prefilter. Whatman™ GD/X Sterile PES Syringe Filters are specifically designed for filtration of viscous or otherwise hard-to-filter samples with high solids content.
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack