DORSAN® syringe filters, manufactured with naturally hydrophobic Polytetrafluorethylene membranes (PTFE). This is the type of membrane most widely used in the preparation of samples for HPLC analysis. PTFE is widely used due to its great resistance to the majority of acid, alkaline and solvent products. Chemically and biologically inert, they
Setting the standard in small-volume filtration (1-200 mL), the unsurpassed consistency of Millex ® syringe filters in sample preparation has led to the development of many methods specifying their use. Featuring reduced sample loss due to minimal hold-up volumes, Millex ® syringe filters are ideal for use in a variety of applications including:
GVS Cameo™ PTFE Syringe Filters without Glass Prefilters For use with aggressive acids, bases and for degassing solvents $257.00 - $1734.00
Finneran 13mm Syringe Filters with glass fiber membranes are available in 1.0um, 2.0um and 5.0um pore sizes. Glass fiber membranes have fast filtration flow, elminate sample contamination and have good chemical compatibility. Finneran syringe filters are autoclavable. Related Products: Syringe Filter.
Syringeless and Syringe Filters. Syringe filters and membranes for the removal of interfering materials and fine particles prior to injection; includes filters both with and without syringes; suitable for both aqueous and aqueous-organic samples; often constructed from PVDF or PTFE.
The pore size of your syringe filter is determined by the size of the particles you need to filter out of your aqueous solution. Syringe filters for aqueous solutions are available in these pore sizes: 0.05 µm, 0.10 µm, 0.22 µm, 0.45 µm, 0.70 µm, 0.80 µm, 1 µm, 3 µm, 5 µm, and 10 µm . As a guide, the finer the pore, the more pressure
Low protein and drug binding characteristics make it ideally suited for use in life sciences applications. These syringe filters are available as sterile or non-sterile, with or without glass fiber prefilter. *NOTE: Due to high demand, 13 and 25 mm diameter syringe filters are experiencing increased lead times. Small Filter Device Resource
25 mm PSF Acrodisc Syringe Filters. Features a large effective filtration area for increased sample throughput, ideal for sample volumes of ≤ 125 mL. Pall’s proprietary membrane technology and accurate pore size ratings offer superior HPLC column protection, helping extend column life by as much as 52 times. Shop Now 25 mm PSF Syringe Filters.
Designed for ultracleaning of small volume samples for the HPLC or GC analysis. Sartorius Minisart™ SRP Syringe Filters are single-use filtration units with a chemically resistant PTFE membrane and male luer slip outlet. Available in 4, 15 and 25mm diameter filters with 0.2 or 0.45 μm pores. Pricing and Availability.
Intro. There are so many solvents and syringe filter/membrane materials that it can be tough to remember which combinations are safe and which are corrosive. These tables show five common syringe filter materials -- Cellulose Acetate (CA), Nylon, PES, PTFE, and PVDF -- and their compatibilities with 75 common solvents.
PTFE Syringe Filters. PTFE syringe filters are hydrophobic and chemically resistant to all solvents, acids, and bases. PTFE does not impart any extractables to the filtrate. It's an ideal material for transducer protectors because it blocks water vapor. PTFE is ideal for filtering and de-gassing chromatography solvents.
Syringe filters are attached to the end of a syringe to remove particles from a sample prior to analysis. Filtering liquids, the single-use devices force liquids through the filter either when fluids are initially drawn or delivered. Circular shaped in diameters that fit common syringe sizes, the cartridges remove fragments that would otherwise damage narrow bore equipment.
0.22 micron 0.45 micron syringe filters nylon Nylon PTFE PES GF glass fiber 13mm 30mm 25mm PVDF Polyvinylidene Fluoride Cellulose Acetate Filter syringe filter
CHROMAFIL® MULTI 96 filter plates. Disposable syringes, PP, with luer tip. HPLC syringe filter ProFill, PTFE. HPLC syringe filter ProFill, RC / PA. LLG Syringe Filter CA, Cellulose acetate. LLG Syringe Filter GF, Glass-fibre. LLG Syringe Filter NY, Nylon/Polyamide. LLG Syringe Filter PE, Polyethylene. LLG Syringe Filter PES, Polyethersulfone.
Hold the syringe with the filter pointing up and “top off” by pushing a few drops through the filter. Place the filter tip over the collection container and push the sample through a syringe filter by applying gentle positive pressure. To purge the syringe filter and maximize sample throughput, remove the filter from the syringe and draw air into the syringe. Then reattach the filter and push the plunger to force some of the air through the filter.
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack