Our experienced scientists and professionals are ready to assist you with any technical support questions. Every question is considered a good question and we will work with you on a solution as fast as possible. Call us: 8:30AM – 6:00PM EST 1-732-380-8900 and hit 0#. Fax to us: 1-910-769-9435. Email Technical Support.
DORSAN® syringe filters, manufactured with naturally hydrophobic Polytetrafluorethylene membranes (PTFE). This is the type of membrane most widely used in the preparation of samples for HPLC analysis. PTFE is widely used due to its great resistance to the majority of acid, alkaline and solvent products. Chemically and biologically inert, they
A variety of membranes are available to meet your needs: Polyethersulfone (PES) – low protein binding and faster flow rates; surfactant-free cellulose acetate (SFCA) – lowest protein binding; polytetrafluorethylene (PTFE) – chemical resistance; regenerated cellulose (RC) – best choice for DMSO compatibility; Nylon (NY) – hydrophilic, surfactant-free, and lowest extractable. 100%
Polypropylene, nylon, and PTFE membranes are ideal for sample preparation and small volume chemical filtration.Syringe filters are attached to the end of a syringe to remove particles from a sample prior to analysis. Filtering liquids, the single-use devices force liquids through the filter either when fluids are initially drawn or delivered. Circular shaped in diameters that fit common
HPLC Syringe Filters headspace vials without admin-Vials Wholesaler Aijiren Tech National Unassembled Headspace Convenience Kits are available for the most popular vial and seal combinations.
Finneran 13mm Syringe Filters with glass fiber membranes are available in 1.0um, 2.0um and 5.0um pore sizes. Glass fiber membranes have fast filtration flow, elminate sample contamination and have good chemical compatibility. Finneran syringe filters are autoclavable. Related Products: Syringe Filter.
Hold the syringe with the filter pointing up and “top off” by pushing a few drops through the filter. Place the filter tip over the collection container and push the sample through a syringe filter by applying gentle positive pressure. To purge the syringe filter and maximize sample throughput, remove the filter from the syringe and draw air into the syringe. Then reattach the filter and push the plunger to force some of the air through the filter.
Jan 25, 2022 · Red polytetra fluorethylene syringe filters. Camlab Choice PTFE filters are red with a chemical compatibility of pH 1-14 and are available in sterile and non-sterile packs. These filters are available in two pore sizes – 0.22 and 0.45µm, and are available in three different syringe filter sizes – 13, 25 and 33mm.
Sterile filtration, clarification, and particle removal. Minisart ® NML Syringe Filters provide the optimal method for clarification and sterilization of liquids, robustly removing bacteria and particles, without any impact on product quality or loss of target molecule. Superior filter areas up to 6.2 cm 2. 0.1µm to 5µm pore sizes.
Titan3 Premium Syringe Filters Target2 Routine Syringe Filters Choice Basic Syringe Filters; Range of filter sizes: 4mm to 30mm: 4mm to 30mm: 13mm to 25mm: High-quality filtration solutions : Low extractable membranes and housing : Plain polypropylene housing : HPLC performance tested : Enhanced Luer Lock inlet which provides secure attachment to syringes
Designed for ultracleaning of small volume samples for the HPLC or GC analysis. Sartorius Minisart™ SRP Syringe Filters are single-use filtration units with a chemically resistant PTFE membrane and male luer slip outlet. Available in 4, 15 and 25mm diameter filters with 0.2 or 0.45 μm pores. Pricing and Availability.
Feb 17, 2020 · Step 2: Attach a syringe filter to the Syringe. Open the syringe filter package so that you can later pick the filter up easily, especially for individually packed sterile syringe filters. a. For sample volume < 10 mL. Draw a small amount of air (about 1 mL) into the syringe before loading the sample solution.
Syringe filters (or wheel filters) are a single-use filter cartridge locate at the end of a syringe. Syringe filters can have luer lock fittings for a secure fit to the syringe. Choose from our wide assortment of filters to suit your application. Syringe filters come in a variety of membrane types. When selecting a syringe filter, be
PTFE Syringe Filters. PTFE syringe filters are hydrophobic and chemically resistant to all solvents, acids, and bases. PTFE does not impart any extractables to the filtrate. It's an ideal material for transducer protectors because it blocks water vapor. PTFE is ideal for filtering and de-gassing chromatography solvents.
Filter Without Syringes found in: Solvent Filtration Disposable Vacuum Bottle Top Filters, Syringe Filter, PVDF, 0.45µm, 30mm Diameter, Syringe Filter,..
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack