PTFE Syringe Filters. PTFE syringe filters are hydrophobic and chemically resistant to all solvents, acids, and bases. PTFE does not impart any extractables to the filtrate. It's an ideal material for transducer protectors because it blocks water vapor. PTFE is ideal for filtering and de-gassing chromatography solvents.
Syringeless and Syringe Filters. Syringe filters and membranes for the removal of interfering materials and fine particles prior to injection; includes filters both with and without syringes; suitable for both aqueous and aqueous-organic samples; often constructed from PVDF or PTFE.
Syringe Filters. Syringe filters are attached to the end of a syringe to remove particles from a sample prior to analysis. Filtering liquids, the single-use devices force liquids through the filter either when fluids are initially drawn or delivered. Circular shaped in diameters that fit common syringe sizes, the cartridges remove fragments
Tisch Scientific Cellulose Acetate (CA) Syringe Filter, 0.22 µm, 33 mm, Luer-Lok/Luer Slip, Sterile, 100 Pack, SF14495. Regular Price $186.51 Price $162.18. Add to Cart. Add to Wish List. Tisch Scientific Cellulose Acetate (CA) Syringe Filter, 1.0 µm, 20 mm, Threaded Double Luer Lock, Nonsterile, 100 Pack, SPEC18179.
Slide 1 of 3. Syringe filters are single-use, membrane-based devices used for the removal of particulate impurities from liquid and gas samples prior to analysis by methods such as HPLC, ion chromatography, gas chromatography, ICP, and dissolution testing. Proper filtration of samples improves the quality and consistency of analytical results
Syringe Filter Selection Guide. Use our quick, interactive syringe filter selection guide to find out what filter is best suited to your analysis. In a few clicks you can submit your recommendations and we will send you a free, personalised sample pack. While you are here you should also look at our filtration products page.
Filters are molded in the polypropylene housings, providing a reliable seal without the use of adhesives Female luer-lock inlet and male luer slip outlet Color coded by membrane type for easy identification, and membrane material and pore size are printed on the housing Available individually packed in peel-to-open paper/plastic blister packs Also available bulk packed in PVDF, PES, PTFE, and
It would be expected that syringe filters containing absolute rated membrane media would be approximately equivalent regardless of supplier for filters that have the same size, same membrane material and same pore size rating. This is not the case for syringe filters containing nominally rated media such as glass fiber or nonwoven polypropylene.
Syringe filters are sterilized by gamma irradiation, preventing the contamination risk that can result from ethylene oxide sterilization. They are individually blister packed to ensure sterility during storage and handling. Replacing a syringe filter midway through the process may lead to contamination, spills, and workflow disruption.
We carry syringe filters made of nylon, glass fiber, polypropylene (PP), polyethersulfone (PES), PVDF, polytetrafluoroethylene (PTFE), cellulose acetate, and more. HPLC Syringe Filters available in two sizes: 13 mm and 30 mm; Two pore sizes: 0.2 µm and 0.45 µm; Glass Fiber syringe filters available in 1.2 and 0.7 µm; Available in 7 color
Feb 17, 2020 · Step 2: Attach a syringe filter to the Syringe. Open the syringe filter package so that you can later pick the filter up easily, especially for individually packed sterile syringe filters. a. For sample volume < 10 mL. Draw a small amount of air (about 1 mL) into the syringe before loading the sample solution.
Syringe filters with cellulose acetate or polyethersulfone membranes are ideal for sterile filtration of buffers, tissue culture media or additives, and other biologicals. The polyethersulfone membrane offers high flow rates. Nonsterile syringe filters are excellent for HPLC applications. Each filter has a female Luer-lock inlet and a male slip
The design of these syringe filters allows them to perform filtration on aqueous as well as organic solvent based samples. Our Polypropylene filters are known for their high throughputs and quick flow rates. *NOTE: Due to high demand, 13 and 25 mm diameter syringe filters are experiencing increased lead times
Jan 25, 2022 · Red polytetra fluorethylene syringe filters. Camlab Choice PTFE filters are red with a chemical compatibility of pH 1-14 and are available in sterile and non-sterile packs. These filters are available in two pore sizes – 0.22 and 0.45µm, and are available in three different syringe filter sizes – 13, 25 and 33mm.
Corning® 50 mm Diameter Syringe Filters, 0.2 µm Pore PTFE Membrane, Sterile, Individually Packaged, 12/Case 1 / Pk 12 / Cs Corning® $158.98: per case: Add to cart
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack