Corning® 50 mm Diameter Syringe Filters, 0.2 µm Pore PTFE Membrane, Sterile, Individually Packaged, 12/Case 1 / Pk 12 / Cs Corning® $158.98: per case: Add to cart
Use these all-plastic disposable syringes with your Titan3, Target2, and Choice Basic syringe filters. Comprising a polypropylene barrel and polyethylene plunger, these syringes eliminate problems with rubber or synthetic plunger gaskets and requires no silicone or oil lubricant in the barrel. Choose from in 1, 3, 5, 10, 20, 30, and 50 mL sizes.
Polypropylene, nylon, and PTFE membranes are ideal for sample preparation and small volume chemical filtration.Syringe filters are attached to the end of a syringe to remove particles from a sample prior to analysis. Filtering liquids, the single-use devices force liquids through the filter either when fluids are initially drawn or delivered. Circular shaped in diameters that fit common
May 14, 2021 · Welded syringe filter has both a layer of PP/GF and a layer of membrane of specified material. Generally, product label notes the second layer of material. As PP/GF materials have strong ability of reserving impurities, they are usually used for pre-filtration of difficult-to-filter solutions. The first layer of double-membrane can absorb most
Filters are molded in the polypropylene housings, providing a reliable seal without the use of adhesives Female luer-lock inlet and male luer slip outlet Color coded by membrane type for easy identification, and membrane material and pore size are printed on the housing Available individually packed in peel-to-open paper/plastic blister packs Also available bulk packed in PVDF, PES, PTFE, and
CHROMAFIL® MULTI 96 filter plates. Disposable syringes, PP, with luer tip. HPLC syringe filter ProFill, PTFE. HPLC syringe filter ProFill, RC / PA. LLG Syringe Filter CA, Cellulose acetate. LLG Syringe Filter GF, Glass-fibre. LLG Syringe Filter NY, Nylon/Polyamide. LLG Syringe Filter PE, Polyethylene. LLG Syringe Filter PES, Polyethersulfone.
Syringe Filter Capabilities. Beyond the extensive product selection found within our standard syringe filter list, we offer OEM capabilities for engineering, molding and insertion of many additional membrane and membrane/pre-filter options.
CHROMAFIL Syringe Filters Feature: Different membrane types to meet multiple filtration applications. Low extractable, sonic welded, leak-free polypropylene housings. Fast flow geometry for minimized back pressure during filtration. Very low hold-up volumes for maximum volume recovery. Certified clean for HPLC and UPLC analysis.
Syringe filters are sterilized by gamma irradiation, preventing the contamination risk that can result from ethylene oxide sterilization. They are individually blister packed to ensure sterility during storage and handling. Replacing a syringe filter midway through the process may lead to contamination, spills, and workflow disruption.
Syringe filters (or wheel filters) are a single-use filter cartridge locate at the end of a syringe. Syringe filters can have luer lock fittings for a secure fit to the syringe. Choose from our wide assortment of filters to suit your application. Syringe filters come in a variety of membrane types. When selecting a syringe filter, be knowledgeable of the filter membrane for your application.
Hold the syringe with the filter pointing up and “top off” by pushing a few drops through the filter. Place the filter tip over the collection container and push the sample through a syringe filter by applying gentle positive pressure. To purge the syringe filter and maximize sample throughput, remove the filter from the syringe and draw air into the syringe. Then reattach the filter and push the plunger to force some of the air through the filter.
How To Use a Syringe Filter. Fill the syringe with the solution to be filtered. Fasten the filled syringe to the FLL inlet of the syringe filter with a twisting motion. With the outlet pointed upward, gradually apply pressure to the syringe plunger to initiate flow. Continue thumb pressure until all the air in the device is displaced with
Intro. There are so many solvents and syringe filter/membrane materials that it can be tough to remember which combinations are safe and which are corrosive. These tables show five common syringe filter materials -- Cellulose Acetate (CA), Nylon, PES, PTFE, and PVDF -- and their compatibilities with 75 common solvents.
Dec 25, 2019 · Syringe filters are available with the following membranes: Nylon, MCE, Polyethersulfone, Polypropylene, PTFE, PVDF and Regenerated Cellulose. Porosities range from 0.1 µm – 10 µm, available filter diameters range from 4 mm (up to 2 ml sample volume) up to 30 mm (up to approx. 200 ml sample volume). Adapted with luer-lock in order to
The pore size of your syringe filter is determined by the size of the particles you need to filter out of your aqueous solution. Syringe filters for aqueous solutions are available in these pore sizes: 0.05 µm, 0.10 µm, 0.22 µm, 0.45 µm, 0.70 µm, 0.80 µm, 1 µm, 3 µm, 5 µm, and 10 µm . As a guide, the finer the pore, the more pressure
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack