A variety of membranes are available to meet your needs: Polyethersulfone (PES) – low protein binding and faster flow rates; surfactant-free cellulose acetate (SFCA) – lowest protein binding; polytetrafluorethylene (PTFE) – chemical resistance; regenerated cellulose (RC) – best choice for DMSO compatibility; Nylon (NY) – hydrophilic, surfactant-free, and lowest extractable. 100%
Polypropylene, nylon, and PTFE membranes are ideal for sample preparation and small volume chemical filtration.Syringe filters are attached to the end of a syringe to remove particles from a sample prior to analysis. Filtering liquids, the single-use devices force liquids through the filter either when fluids are initially drawn or delivered. Circular shaped in diameters that fit common
Syringe Filters MilliporeSigma™ Millex™-GP Sterile Syringe Filter Units with PES Membrane, 0.22 μm (Research Use Only) Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions
Polypropylene Syringe Filters. Sterlitech Polypropylene Syringe Filters are used in a wide array of analytical and research applications for the pharmaceutical, environmental, biotechnological, and agricultural industries. The design of these syringe filters allows them to perform filtration on aqueous as well as organic solvent based samples.
Dec 07, 2020 · Syringe filters are made from a virgin polypropylene housing with a female luer lock inlet and a male slip luer outlet. To use syringe filters, the sample is loaded into a disposable luer syringe. The syringe is then attached to the female luer portion of the syringe filter by securely fastening with a twisting motion.
Acrodisc White Blood Cell (WBC) syringe filter, designed specifically to capture and recover Leukocytes while separating red blood cells and platelets, thereby providing scientists with a simple and efficient method to isolate cells needed for use in a variety of research applications or prepare leukocyte depleted blood for analysis
Minisart ® NML Syringe Filters provide the optimal method for clarification and sterilization of liquids, robustly removing bacteria and particles, without any impact on product quality or loss of target molecule. Superior filter areas up to 6.2 cm 2. 0.1µm to 5µm pore sizes. Low adsorption characteristics.
Syringe Filters. Syringe filters are single-use, membrane-based devices used for the removal of particulate impurities from liquid and gas samples prior to analysis by methods such as HPLC, ion chromatography, gas chromatography, ICP, and dissolution testing. Proper filtration of samples improves the quality and consistency of analytical
Jul 18, 2019 · Syringe Filter Size. Syringe filters range in diameter from 4 mm to 50 mm. The larger the diameter, the more particles can be captured on the filter surface before it begins to block, leading to back pressure and the force that must be applied to the syringe plunger to extract the purified material.
Syringe Filter Capabilities. Beyond the extensive product selection found within our standard syringe filter list, we offer OEM capabilities for engineering, molding and insertion of many additional membrane and membrane/pre-filter options.
Our syringe filters are made with a medical grade polypropylene housing with Luer fittings and sealed using an external ring insert to maintain membrane integrity and best performance. Klarity 25mm, 13mm and 4mm syringe filters are certified for conformance to key tests including bubble point, burst pressure, filter Integrity, water flow rate
Feb 17, 2020 · A PTFE syringe filter is an ideal choice for filtering and de-gassing chromatography solvents. With proper pre-wetting (commonly used alcohol), aqueous samples are also compatible. When using air-vents, these syringe filters are capable of stopping moisture from passing through. Workable pH range: 1-14.
Jan 25, 2022 · These filters are available in two pore sizes – 0.22 and 0.45µm, and are available in three different syringe filter sizes – 13, 25 and 33mm. The PP filters with a 0.22µm pore size have a water flow of 23ml/min/cm 2 and a bubble point of 340kPa. The 0.45µm pore size filters have a water flow of 46ml/min/cm 2 and a bubble point of 220kPa.
Choosing the proper filter size is crucial to avoid rupturing the syringe filter’s housing. As a guide, if the volume of fluid to filter is: 5 to 1.0 ml, then use a 4mm syringe filter; 2-10 ml, then use a 13mm syringe filter; 10-100 ml (or up to 200 ml with a prefilter), then use a 25mm syringe filter; 2-5 L, then use a 50mm syringe filter.
Make sure that the Luer-Lok™ is matching with the syringe to prevent the filter from coming off during the filtration. Filtration. Direct the SiliCycle Syringe Filter tip into the collection vessel and apply gentle pressure onto the syringe plunger. Push the liquid sample and the air volume through the SiliCycle Syringe Filter to maximize
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack