Holding the filter device in one hand and the filled syringe in the other, secure (without excessive force) the filled syringe to the filter device with a twisting motion. Apply gentle pressure to begin filtration. (A gentle pressure helps assure maximum throughput.) CAUTION: As the filter removes particulate, filtration will become more
Sterile Millex ® Syringe Filters Applications include sterilizing cell culture reagents such as cell culture media, antibiotics, supplements, sera, viruses for infection, and other biological solutions Fast flow and low binding for cell culture media preparation with Millipore Express ® PLUS polyethersulfone (PES) membrane
PTFE Syringe Filters. PTFE syringe filters are hydrophobic and chemically resistant to all solvents, acids, and bases. PTFE does not impart any extractables to the filtrate. It's an ideal material for transducer protectors because it blocks water vapor. PTFE is ideal for filtering and de-gassing chromatography solvents.
Feb 17, 2020 · A syringe filter (sometimes called a wheel filter for its wheel-like shape) is a single-use membrane based filter cartridge, to be attached with a syringe to remove impurities in liquid solutions. This pre-filtration step is vital in preventing damage to instruments (e.g. liquid chromatography, ICP, etc.).
Millipore syringe filters are available in a variety of membranes and housing styles to meet your application needs. Ideal for sterile, ion chromatography, and HPLC sample preparation. All syringe filters have a female luer-lock inlet and a male luer slip connector. MORE + $ 149.75 - $ 443.00USD / Pkg of 50
PTFE syringe filter product numbers starting with "PTH" are hydrophilic; all other PTFE syringe filters are hydrophobic. PTFE Hydrophobic Syringe Filters Features: Highly hydrophobic Excellent chemical compatibility Very low extractables Superior flow performance compared to other hydrophobic membranes Applications:
Sterile Millex ® Syringe Filters Applications include sterilizing cell culture reagents such as cell culture media, antibiotics, supplements, sera, viruses for infection, and other biological solutions Fast flow and low binding for cell culture media preparation with Millipore Express ® PLUS polyethersulfone (PES) membrane
The pore size of your syringe filter is determined by the size of the particles you need to filter out of your aqueous solution. Syringe filters for aqueous solutions are available in these pore sizes: 0.05 µm, 0.10 µm, 0.22 µm, 0.45 µm, 0.70 µm, 0.80 µm, 1 µm, 3 µm, 5 µm, and 10 µm . As a guide, the finer the pore, the more pressure
Syringe filter is single-use membrane device, attached to the end of a syringe. Used to remove particulate impurities from samples (liquid/gas) prior to some type of analysis to prevent damage to equipment (e.g. HPLC, chromatography ionic, ICP, dissolution tests etc.) A syringe filter usually consists of a housing with a membrane that serves as
Pall manufactures syringe filters that are used to sterilize liquid reagents, remove particulate contamination, and clarify solutions prior to further processing. These products are optimized for biological, pharmaceutical, and sterilizing filtration requirements. Pall’s sterile syringe filters are available with a variety of high-performance
Syringe filters and other devices A range of syringe filters, accessories, integrated devices, and inline filter-degassers to address laboratory filtration needs from basic to the most demanding, for small research facilities to high-throughput analytical labs. View all products Glass and quartz microfiber filter
Sep 23, 2021 · In a recent paper Vigne, et al., utilized the Pall Acrodisc syringe filters at two different stages in their research looking into the accumulation of Nanostructured Lipid Carriers (NLC) in atherosclerotic plaques 1. Published in 2020, the researchers were employing cutting-edge techniques using NLC to enable the identification in vivo of
Mar 27, 2022 · The particle size determines the pore size you use. For example, use a syringe filter of 0.2-micron pore size to filter out particles larger than 0.2 microns in diameter. Another method for determining column micron size: – use 0.45 μ for microns greater than 3 μ. – use 0.22 μ for microns less than 3 μ.
Syringe filters listed under the limited use category mean the filter’s membrane material may be used in short-term, noncritical applications due to moderate changes in physical properties that may impact your sample.
25 mm PSF Acrodisc Syringe Filters Features a large effective filtration area for increased sample throughput, ideal for sample volumes of ≤ 125 mL Pall’s proprietary membrane technology and accurate pore size ratings offer superior HPLC column protection, helping extend column life by as much as 52 times Shop Now 25 mm PSF Syringe Filters
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack