Glass Prefilter Syringe Filters at Thomas Scientific Syringe filters for convenient filtration of small sample sizes through membranes. This glass microfiber syringe filter can be used as a pre-fil...
Share With:
Description
Inquiry
Description:

Glass Prefilter Syringe Filters at Thomas Scientific

Syringe filters for convenient filtration of small sample sizes through membranes. This glass microfiber syringe filter can be used as a pre-filter to remove interfering particulates before filtering a sample through a membrane. Related Products: Glass Fiber Membrane Filter Compare this item MILLEX® Nonsterile Syringe Filters Glass Fiber Membranes

Syringe Filters - Pall Corporation

Syringe filters with different pore size ratings are suitable for different applications. For example, syringe filters containing 0.45 μm are typically used for HPLC sample preparation and 0.2 μm is used for UHPLC. In life science applications 0.1 and 0.2 µm pore sizes provide sterilization of buffers, culture media, and additives.

Sartorius Minisart™ Plus Syringe Filters - Aijiren Tech Sci

Description. Includes a glass fiber pre-filter for difficult to filter liquids. Sartorius Minisart™ Plus Syringe Filters are single-use, complete filtration units with a surfactant-free cellulose acetate membrane. Choose from three color-coded pore sizes in sterile or non-sterile options. Rapid small volume sterilization.

Glass Microfiber Syringe Filter at Thomas Scientific

a comprehensive syringe filter portfolio used in a variety of applications.Cytiva also offers high-performance GD/X syringe filters with a multi-layer glass fiber prefilter for filtering larger volumes of harder-to-filter samples. Glass microfiber (GMF) membranes Glass microfiber is hydrophilic

Cytiva Whatman™ GD/X Glass Fiber (GF) Syringe Filters

Whatman™ GD/X Glass Fiber (GF) Syringe Filters are specifically designed for filtration of viscous or otherwise hard-to-filter samples with high solids content. Constructed of a polypropylene housing with a prefiltration stack of Whatman GMF 150 (graded density) and GF/F glass microfiber prefilters.

Syringe Filters for Sterile Filtration | Minisart® | Sartorius

Minisart ® NML Syringe Filters provide the optimal method for clarification and sterilization of liquids, robustly removing bacteria and particles, without any impact on product quality or loss of target molecule. Superior filter areas up to 6.2 cm 2. 0.1µm to 5µm pore sizes. Low adsorption characteristics.

Syringe Filters from Cole-Parmer

Shop Our Best Sellers. Cole-Parmer Essentials Sterilized Air Filter; 0.2µm Pore, 50mm Di. EW-15945-22. Cole-Parmer Essentials PTFE Chromatography Syringe Filter, 0.2µm. EW-15945-42. Cole-Parmer Essentials PTFE Chromatography Syringe Filter, 0.45µm. EW-15945-43. Cole-Parmer Nylon Chromatography Syringe Filter, 0.45um.

Glass Fiber Syringe Filters - Laboratory Sales

These glass fiber syringe filters are designed for clarification of extremely viscous samples that may clog a membrane syringe filter and has a high loading ability for high throughputs. They have a hydrophilic membrane and are compatible with organic solvents and strong acids (not hydrofluoric) and bases. High dirt handling capability.

Glass Fiber Syringe Filters - Pall Corporation

Pall supplies both traditional ring moulded 25 mm glass fiber syringe filters and Premium Syringe Filter (PSF) 25 mm glass fiber syringe filters. The PSF syringe filter has a much larger effective filtration area compared with the older traditional model, 3.9 cm 2 compared to 2.8 cm 2. This gives the PSF syringe filter an improved throughput and flow rate. The housing for both types of syringe filters is constructed out of broad chemical compatible polypropylene material.

How to Select a Syringe Filter and How to Use it? (2020 Guide)

Step 2: Attach a syringe filter to the Syringe. Open the syringe filter package so that you can later pick the filter up easily, especially for individually packed sterile syringe filters. a. For sample volume < 10 mL. Draw a small amount of air (about 1 mL) into the syringe before loading the sample solution.

Glass Fiber Syringe Filters - Sterlitech

Glass Fiber syringe filters act as a valuable prefilter to extend membrane life with viscous samples. For hard-to-filter samples such as tissue culture media or samples with large particulate loads. Glass Fiber Syringe Filter Availability: Pore Sizes: 0.7 µm to 3.1 µm; Diameter: 25 & 30 mm

Syringe Filter, Glass Fiber, 25mm, 1um (Pack of 100)

Manufactured from borosilicate glass fiber - Manufactured according to ISO9001 certified quality management system - The filter membrane meets the criteria non-fiber releasing filters as defined in 21 CFR 210.3(B)(6) - Large surface area and high flow rate - Applications: Pre-filter for membranes especially for thick sample solutions.

0.22/0.45 um Glass Fiber Membrane Syringe Filter Manufacturer

Hawach glass fiber syringe filters with a retention efficiency of 98%, also used as a pre-filter for microbiological filtering. Skip to content +86-29-89284429.

CHROMAFIL ® Syringe Filters – Glass Fiber (GF) - Sorbtech

Syringe Filters – Glass Fiber (GF) Inert filter, nominal pore size 1 µm, allows higher flow rates than small pore filters. For solutions with high loads of particulate matter or for highly viscous solutions (e. g. soil samples, fermentation broths) As prefilters for other CHROMAFIL ® filters, prevents membrane plugging.