Feb 17, 2020 · A syringe filter (sometimes called a wheel filter for its wheel-like shape) is a single-use membrane based filter cartridge, to be attached with a syringe to remove impurities in liquid solutions. This pre-filtration step is vital in preventing damage to instruments (e.g. liquid chromatography, ICP, etc.).
National “VAWD” accredited distributor offering competitively priced Safety, Syringe Filters nationwide. Providing useful solutions to customer needs for 29 years.
Hold the syringe with the filter pointing up and “top off” by pushing a few drops through the filter. Place the filter tip over the collection container and push the sample through a syringe filter by applying gentle positive pressure. To purge the syringe filter and maximize sample throughput, remove the filter from the syringe and draw air into the syringe. Then reattach the filter and push the plunger to force some of the air through the filter.
Filters are molded in the polypropylene housings, providing a reliable seal without the use of adhesives Female luer-lock inlet and male luer slip outlet Color coded by membrane type for easy identification, and membrane material and pore size are printed on the housing Available individually packed in peel-to-open paper/plastic blister packs Also available bulk packed in PVDF, PES, PTFE, and
Syringe filters (or wheel filters) are a single-use filter cartridge locate at the end of a syringe. Syringe filters can have luer lock fittings for a secure fit to the syringe. Choose from our wide assortment of filters to suit your application. Syringe filters come in a variety of membrane types. When selecting a syringe filter, be
Gilson SupaTop Syringe Filters offer reliable and cost-effective solutions for particles removal and clarification needs. With a body made of pigment-free polypropylene, the syringe filters are certified for low levels of UV-absorbing extractables. A large variety of membranes are available for all applications: MCE, Nylon, PTFE, PES or PVDF.
PTFE Syringe Filters. PTFE syringe filters are hydrophobic and chemically resistant to all solvents, acids, and bases. PTFE does not impart any extractables to the filtrate. It's an ideal material for transducer protectors because it blocks water vapor. PTFE is ideal for filtering and de-gassing chromatography solvents.
Gilson SupaTop Syringe Filters offer reliable and cost-effective solutions for particles removal and clarification needs. With a body made of pigment-free polypropylene, the syringe filters are certified for low levels of UV-absorbing extractables. A large variety of membranes are available for all applications: MCE, Nylon, PTFE, PES or PVDF.
Jul 18, 2019 · In scientific applications, the most common sizes available are 0.2 or 0.22 µm and 0.45 µm pores. These sizes are sufficient for HPLC use. The smallest known sterile syringe micro filter have pore sizes of 0.02 µm. Membrane diameters of 13 mm, 25 mm and 30/33 mm are common as well. The syringe filter body may be made of such materials as
0.22 micron 0.45 micron syringe filters nylon Nylon PTFE PES GF glass fiber 13mm 30mm 25mm PVDF Polyvinylidene Fluoride Cellulose Acetate Filter syringe filter
Syringe Filters MilliporeSigma™ Millex™-GP Sterile Syringe Filter Units with PES Membrane, 0.22 μm (Research Use Only) Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions
Triple Layered Syringe Filter. Triple Layered Syringe Filter - Nylon Membrane with two layers of Glass Fiber Filter. Nylon Membrane 25mm 0.2um; Nylon Membrane 25mm 0.45um; Triple Layered Syringe Filter - PVDF Membrane with two layers of Glass Fiber Filter. PVDF Membrane 25mm 0.2um; PVDF Membrane 25mm 0.45um; Grade 1 Qualitative Filter Paper
Dec 07, 2020 · The main selection criteria for your syringe filter membrane is solvent compatibility and application (specifically, if you are concerned with protein binding). Nylon membranes are used for general laboratory filtration of HPLC samples prior to injection. Nylon is solvent resistant, exhibits lows extractables, and is compatible with both
The syringe filter body may be made of such materials as polypropylene and nylon. The filter membrane may be of PTFE, nylon, or other treated products for specific purposes.
Description Syringe Filters, Polypropylene Body - Polypropylene Membrane. Extended Description Hydrophilic Polyethersulfone media filter discs within a medical grade Polypropylene housing designed for in-line filtration. Product Information Full product data will be available on configuration of part
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack