Water and acetonitrile were passed through polypropylene or PTFE syringe filters (as indicated in legend), then used 1:1 (v/v) to prepare the mobile phase for UHPLC. The system was run at 0.25 mL/min for 600 min with backpressure recorded every 50 min. DP represents total change in backpressure after 600 min.
Minisart ® NML Syringe Filters provide the optimal method for clarification and sterilization of liquids, robustly removing bacteria and particles, without any impact on product quality or loss of target molecule. Superior filter areas up to 6.2 cm 2. 0.1µm to 5µm pore sizes. Low adsorption characteristics.
Syringe Filters MilliporeSigma™ Millex™-GP Sterile Syringe Filter Units with PES Membrane, 0.22 μm (Research Use Only) Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions
Puradisc™ FP Syringe Filter. Syringe Filter, Puradisc™ FP, 1.2 µm Pore Size, Up to 100 ml, 26 x 34 mm, 30 mm dia Membrane, Cellulose Acetate Membrane, Sterile, Polycarbonate Housing Material, Autoclavable, For Routine Syringe Filtration. Syringe Filter, Puradisc™ FP, 1.2 µm Pore Size, Up to 100 ml, 26 More SECO Part #: 12-4458-05.
100 Pack Syringe Filter PTFE Hydrophobic 0.22um Membrane 13mm Pore Size Filtration Non-Sterile Syringe Lab Filters. $2999 ($3.00/10 Items) Save $6.00 with coupon. Get it as soon as Thu, May 19. FREE Shipping by Amazon. Only 2 left in stock - order soon.
It would be expected that syringe filters containing absolute rated membrane media would be approximately equivalent regardless of supplier for filters that have the same size, same membrane material and same pore size rating. This is not the case for syringe filters containing nominally rated media such as glass fiber or nonwoven polypropylene.
Corning® 50 mm Diameter Syringe Filters, 0.2 µm Pore PTFE Membrane, Sterile, Individually Packaged, 12/Case 1 / Pk 12 / Cs Corning® $158.98: per case: Add to cart
Biofil™ syringe filters design with a layer of prefilter. Ideal for filtering the solutions with a high load of particulate matter. All the Syringe filters are well packed, with competitive price filters. The membranes range from Nylon, CA, MCE, PES, PTFE, PVDF, GF, Regenerated Cellulose (RC) to PP, which are supplied in 13mm and 25mm no
Syringe Filters. Pall supplies a comprehensive family of syringe filters offering a full range of sizes, volumes, and flow rates. Sterile syringe filters are typically used in life science applications to sterilize solutions or for clarification. Non-sterile syringe filters are used across a range of filtration and sample preparation applications. They are widely used in analytical chemistry for sample preparation, protecting analytical equipment from particle contamination.
Filters Syringe Filters. Available with either cellulose acetate or PES membrane. Sterile membranes with 0,2 µm pore size are ideal for sterile filtration applications, whilst those with 0,45 µm pore size can be used for clarifications. These sterile syringe filters are gamma irradiated to prevent cytotoxic residues caused by alternative
BASKET SHAFTS The rotating basket assembly is individually serialized with the serial number laser imprinted on the shaft for record keeping purposes. These assemblies meet USP specifications requiring three retention spring clips for Apparatus 1 or o-ring push-on style.
Syringe filters are sterilized by gamma irradiation, preventing the contamination risk that can result from ethylene oxide sterilization. They are individually blister packed to ensure sterility during storage and handling. Replacing a syringe filter midway through the process may lead to contamination, spills, and workflow disruption.
25 mm PSF Acrodisc Syringe Filters. Features a large effective filtration area for increased sample throughput, ideal for sample volumes of ≤ 125 mL. Pall’s proprietary membrane technology and accurate pore size ratings offer superior HPLC column protection, helping extend column life by as much as 52 times. Shop Now 25 mm PSF Syringe Filters.
Feb 17, 2020 · Step 2: Attach a syringe filter to the Syringe. Open the syringe filter package so that you can later pick the filter up easily, especially for individually packed sterile syringe filters. a. For sample volume < 10 mL. Draw a small amount of air (about 1 mL) into the syringe before loading the sample solution.
Syringe Filters for Dissolution. Cronus syringe filters are fully validated and tested by an independent laboratory for each individual batch to ensure complete reproducibility and the lowest levels of extractables. PVDF and Glass Microfibre are popular membranes for dissolution media. GMF is useful for high particulate samples.
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack