High performance sterile and nonsterile syringe filters offered in a variety of membrane materials and pore sizes, tailored for sample preparation for HPLC, UHPLC, ion chromatography, dissolution testing, and other analyses.
Aijiren Tech™ Target2™ PTFE Syringe Filters Catalog number: F2513-4 Related applications: Chromatography Technical Support Customer Service Adding a syringe filtration step prior to injection not only helps to ensure more consistent and reliable results; it also helps protect delicate instruments and prolongs column life.
A syringe filter (sometimes called a wheel filter if it has a wheel-like shape) is a single-use filter cartridge. It is attached to the end of a syringe for use. Syringe filters may have Luer lock fittings, though not universally so. The use of a needle is optional; where desired it may be fitted to the end of the syringe filter.
How to use a Syringe Filter for embryo handling. This syringe filter has a low protein binding membrane to maximize recovery of critical components. Gamma
For use with heavy particulate samples, these filtration devices contain two or more filter layers to allow efficient filtration without blockage. A cost-effective, efficient solution that minimizes waste. These sturdy syringe filters are compatible with most high throughput and/or dissolution systems. The workhorse of the lab, high performance
Syringe Filters / Non-Sterile Syringe Filters Non-Sterile Syringe Filters Pall supplies a range of non sterile syringe filters that can be used across a range of sample preparation applications. Pall’s Acrodisc® syringe filters can be used for prefiltation, general filtration and in critical analytical sample preparation applications.
Product Support. Whatman™ Uniflo™ Syringe Filters are disposable filter units designed to provide clean filtrate from small volumes up to 100 mL. They are available in a variety of membrane choices with a polypropylene overmold housing, and include both sterile and non-sterile options. 13 mm, 25 mm or 30 mm diameters. 0.2 μm or 0.45 μm
A syringe filter (or wheel filter) is a single-use, membrane-based device used for the removal of particulate impurities from small (≤ 100 mL) liquid samples (Figure 1). Selected based upon the desired end application, disposable syringe filters are commonly used in labs for fast and efficient filtering, material purification, or even sterilization.
Syringe filters are single use, self contained, filtration devices that are typically used to remove contaminating particulate from liquids or gasses. When selecting the correct syringe filter for an application there are a number of factors to consider, these include: Filter and housing materials Pore size Effective filtration area Hold-up volume
What are syringe filters? Syringe filters are single-use filtration devices that are made up of a membrane, or combination of membranes, placed inside molded housing. The connections on the device are commonly Luer lock or Luer slip and enable a quick connection to syringes, that are used to pass the liquid sample through the filter.
Dec 13, 2022 · What Is A Syringe Filter Used For? A single-use, membrane-based device is used to remove particulate impurities from liquid and gas samples prior to analysis by methods such as HPLC, ion chromatography, gas chromatography, ICP, and dissolution testing. What Size Syringe Filter Do I Need? The size of the sample determines the size of the syringes.
The product line includes pore sizes ranging from 0.1 μm to 5.0 μm to ensure a comprehensive selection of syringe filters are available. Syringe filters are sterilized by gamma irradiation, preventing the contamination risk that can result from ethylene oxide sterilization. They are individually blister packed to ensure sterility during storage and handling. Replacing a syringe filter midway through the process may lead to contamination, spills, and workflow disruption.
Feb 17, 2020 · A syringe filter (sometimes called a wheel filter for its wheel-like shape) is a single-use membrane based filter cartridge, to be attached with a syringe to remove impurities in liquid solutions. This pre-filtration step is vital in preventing damage to instruments (e.g. liquid chromatography, ICP, etc.).
Performing a syringe filtration step prior to chromatographic injection helps to ensure more consistent and reliable results, and helps to protect delicate instruments and prolong column life. Choice PES Syringe Filters 0.2 µm, 25 mm, 100 Pk. Choice PES Syringe Filters 0.45 µm, 25 mm, 100 Pk. Choice PES Syringe Filters 0.2 µm, 13 mm, 100 Pk.
Mar 27, 2022 · The hydrophobic type of syringe filter is generally used for gas filtration. If we use hydrophilic type PTFE or PVDF, it means we need to apply it to filtration of liquids (organic solvents, strong acids, alkalis, and aqueous solutions). It is also possible to filter organic solvents using hydrophobic membranes, such as ethanol, etc.
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack