Syringe Filters - Pall Corporation

Syringe filters are single use, self contained, filtration devices that are typically used to remove contaminating particulate from liquids or gasses. When selecting the correct syringe filter for an application there are a number of factors to consider, these include: Filter and housing materials. Pore size. Effective filtration area.

AQ™ Syringe Filters - Microsolv Technology Corporation

These syringe filters are recommended for "pharmaceutical" grade HPLC Sample Prep & Dissolution Testing when GLP and GMP are required. Manufactured with proprietary and various membrane types in 25mm, 13mm or 4mm polypropylene housings. These color coded, syringe filters are also made for laboratories that require consistent, high performance

Introduction And Tips Of Using Syringe Filters - Hawach

Syringe filter is the preferred alternative for HPLC or GC sample filtering, usually matching with disposable syringe, with filter diameter from 4mm to 50mm, and capacity from 0.5ml to 200ml. In HPLC analysis, the column packing particle size is small and easily blocked by impurity particles, so the sample and solvent need to be pre-filtered to

Syringe Filters - 5um

PVDF Syringe Filters, 5 um, 25mm, Double Luer Lock, PP Housing, sterile, 100 per pack, SPEC18216. Regular Price $182.77 Price $158.93. Add to Cart. Polypropylene Syringe Filters, 5 um, 20mm, Threaded Double Luer Lock, ABS Housing, Nonsterile, 100 per pack, SPEC18201. Regular Price $101.54 Price $88.30 As low as $79.47.

Syringes and Syringe Filters | FieldTech Solutions

Product ID Syringe_and_Filters. Using syringes for groundwater filtration in the field is a popular low-cost option. It can be an ideal choice if you are not using a pump, and have a manual device such as a bailer. When using a syringe 50ml at a time can be pushed through a filter. Small low-capacity filters can be used where turbidity is low.

Syringe Filters • CELLTREAT Scientific Products

Filters are molded in the polypropylene housings, providing a reliable seal without the use of adhesives Female luer-lock inlet and male luer slip outlet Color coded by membrane type for easy identification, and membrane material and pore size are printed on the housing Available individually packed in peel-to-open paper/plastic blister packs Also available bulk packed in PVDF, PES, PTFE, and

syringe filter tip | English to Greek | Medical: Instruments

Jan 24, 2012 · Pre-Filled Syringe- If using XXX in the pre-filled syringe, first depress the plunger to eliminate excess air space from the barrel. Next, place the filter tip end of the syringe into a sterile bowl containing saline or blood. Pull up on the plunger to draw the liquid up through the graft particles and then expel any excess liquid. Remove the filter tip to dispense the hydrated bone graft

Syringe Tip Filter at Thomas Scientific

13mm Mini-Tip Syringe Filters J.G. Finneran Finneran 13mm Mini-Tip Syringe Filters provide extremely low dead volume of less than 10ul, and are available in 0.2um and 0.45um pore sizes. Autoclavable. Related Products: 13mm Syringe Filter Compare this item Syringe Filters Celltreat Scientific

Syringe Filters | Aijiren Tech Scientific - US

Use these all-plastic disposable syringes with your Titan3, Target2, and Choice Basic syringe filters. Comprising a polypropylene barrel and polyethylene plunger, these syringes eliminate problems with rubber or synthetic plunger gaskets and requires no silicone or oil lubricant in the barrel. Choose from in 1, 3, 5, 10, 20, 30, and 50 mL sizes.

HPLC Syringe Filter

Non-sterile Disposable Syringe Filter Syringe Filter PTFE for HPLC Syringe Filter Nylon for Laboratory Syringe Filter PVDF for Sale Sterile Syringe Filters Wholesale Syringe Filter MCE for Lab Use 0.22μm Pore Syringe Filters for Sale 25mm Syringe Filter for Sale 13mm Syringe Filters Wholesale 0.45μm Syringe Filtre Wholesale Price

Corning SFCA Syringe Filters:Filters and - Aijiren Tech Scientific

Pore size and membrane type is printed on every syringe filter. Sterile filters are individually blister-wrapped in cases of 50, nonsterile in cases of 50. Compliance. Manufactured to ISO 9002 and GMP standards, and 100% integrity tested.

Best Sellers in Syringe Lab Filters - amazon.com

Best Sellers in Syringe Lab Filters. #1. 10 Pack Syringe Filter Sterile PES Hydrophilic Filtration 0.22um Pore Size, 33mm Membrane Diameter Sterile PES Membrane Individually Packed by Membrane Solutions. 4.5 out of 5 stars. 474. 3 offers from $13.99. #2. Biomed Scientific Syringe Filters PTFE 13mm Diameter 0.22um Pore Size Non Sterile Pack of 10.

Syringe Filters - SiliCycle

Twist the SiliCycle Syringe Filter Luer-Lok™ onto the syringe. Make sure that the Luer-Lok™ is matching with the syringe to prevent the filter from coming off during the filtration. Filtration. Direct the SiliCycle Syringe Filter tip into the collection vessel and apply gentle pressure onto the syringe plunger.

Minisart® Syringe Filters | Sterile Filtration | Sartorius

Minisart ® Syringe Filters: The Industry Leading Syringe Filter - Turning Science into Solutions. Sartorius offers Minisart ® syringe filters for a wide range of applications, including sterile filtration. Our filters are clean and safe as they are almost free of leachables and exractables and ultralow absorption properties.

Syringe Filters - Sigma-Aldrich

If you are using a leur lock filter, ensure you have correctly secured the filter into the syringe tip. Hold the syringe with the filter pointing up and “top off” by pushing a few drops through the filter. Place the filter tip over the collection container and push the sample through a syringe filter by applying gentle positive pressure. To purge the syringe filter and maximize sample throughput, remove the filter from the syringe and draw air into the syringe. Then reattach the filter