Syringe filters are single use, self contained, filtration devices that are typically used to remove contaminating particulate from liquids or gasses. When selecting the correct syringe filter for an application there are a number of factors to consider, these include: Filter and housing materials Pore size Effective filtration area Hold-up volume
Oct 20, 2021 · The biggest advantage to using a filter vial is that the sample is always contained, and the filtration is a single step that doesn’t require transfer to a vial for analysis. Syringe filters are more economical, and for this reason are generally more popular among labs. We keep many different syringe filter sizes and membrane options in stock
While the primary function of a syringe filter is to remove particulates from a liquid sample, you will select either a sterile or non-sterile filter, depending on the end application. Sterile syringe filters are used to sterilize non-sterile solutions or clarify sterile solutions.
Choosing the proper filter size is crucial to avoid rupturing the syringe filter’s housing. As a guide, if the volume of fluid to filter is: 5 to 1.0 ml, then use a 4mm syringe filter; 2-10 ml, then use a 13mm syringe filter; 10-100 ml (or up to 200 ml with a prefilter), then use a 25mm syringe filter; 2-5 L, then use a 50mm syringe filter.
A variety of membranes are available to meet your needs: Polyethersulfone (PES) – low protein binding and faster flow rates; surfactant-free cellulose acetate (SFCA) – lowest protein binding; polytetrafluorethylene (PTFE) – chemical resistance; regenerated cellulose (RC) – best choice for DMSO compatibility; Nylon (NY) – hydrophilic, surfactant-free, and lowest extractable. 100%
DORSAN® syringe filters, manufactured with naturally hydrophobic Polytetrafluorethylene membranes (PTFE). This is the type of membrane most widely used in the preparation of samples for HPLC analysis. PTFE is widely used due to its great resistance to the majority of acid, alkaline and solvent products. Chemically and biologically inert, they
PTFE Syringe Filters. PTFE syringe filters are hydrophobic and chemically resistant to all solvents, acids, and bases. PTFE does not impart any extractables to the filtrate. It's an ideal material for transducer protectors because it blocks water vapor. PTFE is ideal for filtering and de-gassing chromatography solvents.
Syringe filters (or wheel filters) are a single-use filter cartridge locate at the end of a syringe. Syringe filters can have luer lock fittings for a secure fit to the syringe. Choose from our wide assortment of filters to suit your application. Syringe filters come in a variety of membrane types. When selecting a syringe filter, be
A syringe filter is a single-use filter cartridge. It is attached to the end of a syringe for use. Syringe filters may have Luer lock fittings, though not universally so. The use of a needle is optional; where desired it may be fitted to the end of the syringe filter. A syringe filter generally consists of a plastic housing with a membrane that serves as a filter. The fluid to be purified may be cleaned by drawing it up the syringe through the filter, or by forcing the unfiltered fluid through t
Water Designated as Essential Function during COVID-19 Emergency; State Water Control Board in CA COVID-19 Survey; Cannabis Syringe Filters; Face Masks; Product Type.
The price of syringe filters is divided into one-time and multi-time, organic or water-based, the specifications are Φ13 or Φ25, used for sample filtration in liquid or gas phase analysis. Filter materials include: nylon (Nylon) , polyvinylidene fluoride (PVDF), polytetrafluoroethylene (PTFE), mixed cellulose (MCE) , cellulose acetate (CA
Minisart ® NML Syringe Filters provide the optimal method for clarification and sterilization of liquids, robustly removing bacteria and particles, without any impact on product quality or loss of target molecule. Superior filter areas up to 6.2 cm 2. 0.1µm to 5µm pore sizes. Low adsorption characteristics.
Feb 17, 2020 · A syringe filter (sometimes called a wheel filter for its wheel-like shape) is a single-use membrane based filter cartridge, to be attached with a syringe to remove impurities in liquid solutions. This pre-filtration step is vital in preventing damage to instruments (e.g. liquid chromatography, ICP, etc.).
The present invention relates to a disposable syringe having a safety filter function, comprising a safety filter unit installed and fixed over an internal bottom surface of a cylinder and an internal upper part of a neck formed on a lower end of the cylinder.
Our 25 mm syringe filters use the identical materials of construction as our entire capsule filter portfolio to ensure streamlined scaling without requalification or revalidation concerns. From our syringe filters with 4 cm 2 of surface area to our 50″ UltraCap ® H.D. filters with up to 3.6 m 2 of surface area, the only thing that changes as
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack