Available in 4, 13, 25, 33, and 50 mm diameters with a variety of membranes, Millex ® sterile syringe filters are ideal for sterilizing organic solvents, aqueous solutions or air/gas. Many sample preparation methods specify Millex® filters because of their unsurpassed quality and consistency. Millex ® filters not only feature minimal hold-up
Hold the syringe with the filter pointing up and “top off” by pushing a few drops through the filter. Place the filter tip over the collection container and push the sample through a syringe filter by applying gentle positive pressure. To purge the syringe filter and maximize sample throughput, remove the filter from the syringe and draw air into the syringe. Then reattach the filter and push the plunger to force some of the air through the filter.
Check out our syringe filter selection for the very best in unique or custom, handmade pieces from our shops.
Make sure that the Luer-Lok™ is matching with the syringe to prevent the filter from coming off during the filtration. Filtration. Direct the SiliCycle Syringe Filter tip into the collection vessel and apply gentle pressure onto the syringe plunger. Push the liquid sample and the air volume through the SiliCycle Syringe Filter to maximize
Syringe Filter Selection Guide. Use our quick, interactive syringe filter selection guide to find out what filter is best suited to your analysis. In a few clicks you can submit your recommendations and we will send you a free, personalised sample pack. While you are here you should also look at our filtration products page.
Syringe filters are single use, self contained, filtration devices that are typically used to remove contaminating particulate from liquids or gasses. When selecting the correct syringe filter for an application there are a number of factors to consider, these include: Filter and housing materials. Pore size. Effective filtration area.
Jul 18, 2019 · Syringe filters range in diameter from 4 mm to 50 mm. The larger the diameter, the more particles can be captured on the filter surface before it begins to block, leading to back pressure and the force that must be applied to the syringe plunger to extract the purified material. The size of the syringe filter is up to the diameter of the membrane filter inside of it.
0.22 µm Syringe Filter, Cellulose Acetate (Sterile), Blue, ⌀ 33 mm distribution and any kind of use and utilization of this PDF content in electronic systems ...
LabZhang 24pcs Syringe Filter,Syringe Lab Filters,PES Hydrofilic Membrane 25mm Diameter 0.22um Pore Size,Non Sterile Filtration,Yellow(PES-25mm 0.22um) 4.3 out of 5 stars 52 1 offer from $12.99
Selection Guide for Syringe Filters. To find the right syringe filter for your application, follow the steps below: 1. Determine the filter size: 3 mm: for sample volumes < 1 ml 15 mm: for sample volumes 1 - 10 ml 25 mm: for sample volumes > 10 ml. 2. Determine the pore size: 0.20 μm: recommended for UHPLC and HPLC columns with pore sizes < 3 μm
Filters are molded in the polypropylene housings, providing a reliable seal without the use of adhesives Female luer-lock inlet and male luer slip outlet Color coded by membrane type for easy identification, and membrane material and pore size are printed on the housing Available individually packed in peel-to-open paper/plastic blister packs Also available bulk packed in PVDF, PES, PTFE, and
Tisch Scientific Cellulose Acetate (CA) Syringe Filter, 3.0 µm, 20 mm, Threaded Double Luer Lock, Nonsterile, 100 Pack, SPEC18180. Regular Price $119.46 Price $103.88 As low as $93.49. Add to Cart. Add to Wish List. Tisch Scientific Cellulose Acetate (CA) Syringe Filter, 0.45 µm, 33 mm, Luer-Lok/Luer Slip, Nonsterile, 100 Pack, SF14490.
It would be expected that syringe filters containing absolute rated membrane media would be approximately equivalent regardless of supplier for filters that have the same size, same membrane material and same pore size rating. This is not the case for syringe filters containing nominally rated media such as glass fiber or nonwoven polypropylene.
Dec 07, 2020 · The main selection criteria for your syringe filter membrane is solvent compatibility and application (specifically, if you are concerned with protein binding). Nylon membranes are used for general laboratory filtration of HPLC samples prior to injection. Nylon is solvent resistant, exhibits lows extractables, and is compatible with both
ISOLAB USA - Syringe Filters. Pack of 100. PTFE Membrane 25mm Diameter 0.45um Pore Size Non Sterile. Water, Chemicals and Beverage Filtration. 12. $3970 ($3.97/10 Items) $35.73 with Subscribe & Save discount. Get it as soon as Mon, May 16. FREE Shipping by Amazon.
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack