Minisart ® NML Syringe Filters provide the optimal method for clarification and sterilization of liquids, robustly removing bacteria and particles, without any impact on product quality or loss of target molecule. Superior filter areas up to 6.2 cm 2. 0.1µm to 5µm pore sizes. Low adsorption characteristics.
Syringe filters are attached to the end of a syringe to remove particles from a sample prior to analysis. Filtering liquids, the single-use devices force liquids through the filter either when fluids are initially drawn or delivered.
Syringe filters are single use, self contained, filtration devices that are typically used to remove contaminating particulate from liquids or gasses. When selecting the correct syringe filter for an application there are a number of factors to consider, these include: Filter and housing materials. Pore size. Effective filtration area.
Reusable Syringe Filter: Filter Medium: Reusable: Diameter(mm) 25: Pore Size(μm) Wettability: Sterile: Prefilter: Filtration Area(cm²) 2.98: Housing Material: PP: Holdup-Volume(μl) None: Volume Throughput(ml) None: Connections(Inlet/Outlet) Female Luer-Sip inlet and Male Luer slip outlet: Max Operating Pressure(psi) 87: Max Operating
Syringe Filters Syringe Filters Syringe filters (or wheel filters) are a single-use filter cartridge locate at the end of a syringe. Syringe filters can have luer lock fittings for a secure fit to the syringe. Choose from our wide assortment of filters to suit your application. Syringe filt MORE + Plastic syringes — luer-slip, luer-lock and more.
Hold the syringe with the filter pointing up and “top off” by pushing a few drops through the filter. Place the filter tip over the collection container and push the sample through a syringe filter by applying gentle positive pressure. To purge the syringe filter and maximize sample throughput, remove the filter from the syringe and draw air into the syringe. Then reattach the filter and push the plunger to force some of the air through the filter.
Oct 18, 2021 · For example, how to choose a syringe filter in LCMS, how to choose a filter membrane when the solvent is unknown, whether there is a universal membrane that can be used in the world, etc. All trouble the experimenters in daily experimental work. Usually, we pay attention to several important parameters when selecting products based on applications.
Membrane Solutions Sterile PES Syringe Filters 0.22um Pore Size, 33mm Membrane Diameter . MS sterile syringe filters are made with a wide variety of membrane filters with polypropylene (PP) housing, using the most advanced methods and design features. The most commonly types membrane for sterile syringe filters are PES and PES with GF pre-filter.
Corning® 50 mm Diameter Syringe Filters, 0.2 µm Pore PTFE Membrane, Sterile, Individually Packaged, 12/Case 1 / Pk 12 / Cs Corning® $158.98: per case: Add to cart
Filters are molded in the polypropylene housings, providing a reliable seal without the use of adhesives Female luer-lock inlet and male luer slip outlet Color coded by membrane type for easy identification, and membrane material and pore size are printed on the housing Available individually packed in peel-to-open paper/plastic blister packs Also available bulk packed in PVDF, PES, PTFE, and
Syringeless and Syringe Filters. Syringe filters and membranes for the removal of interfering materials and fine particles prior to injection; includes filters both with and without syringes; suitable for both aqueous and aqueous-organic samples; often constructed from PVDF or PTFE.
CHROMAFIL Syringe Filters Feature: Different membrane types to meet multiple filtration applications. Low extractable, sonic welded, leak-free polypropylene housings. Fast flow geometry for minimized back pressure during filtration. Very low hold-up volumes for maximum volume recovery. Certified clean for HPLC and UPLC analysis.
0.22 micron 0.45 micron syringe filters nylon Nylon PTFE PES GF glass fiber 13mm 30mm 25mm PVDF Polyvinylidene Fluoride Cellulose Acetate Filter syringe filter
QGA Syringe Filters, Bag of 25. Overview. Details. Parameter/Reagent. Would you like to use our Product Configurator tool to configure this product before adding it to your cart? If not, you may add it directly to your cart. Product #: DIS-SFQG-25. USD Price: $89.10.
Syringe filters are sterilized by gamma irradiation, preventing the contamination risk that can result from ethylene oxide sterilization. They are individually blister packed to ensure sterility during storage and handling. Replacing a syringe filter midway through the process may lead to contamination, spills, and workflow disruption.
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack