Feb 17, 2020 · What’s the syringe filter diameter to be chosen? 13mm or 25mm? All filter inlets are female Luer-Lock compatible, have inert polypropylene housings and come in three diameters. The diameter is determined by the volume to be filtered. 13 mm Syringe Filters. For sample volumes <10 mL range; Ideal choice for most applications;
Introduction. MS ® PTFE syringe filters are purpose-built with features designed to bring the highest levels of performance and purity to your research. We incorporate a variety of membranes to offer separation and purification solutions for the majority of your laboratory needs. PTFE Syringe Filter.
DNA Extraction OEM Services; Embed™ Universal CPG Frits Columns; PES Syringe Filters: Details: 1/1 Product Category. Sample Prep. Copure® QuEChERS .
Our filters are available in a variety of sizes and membranes that can be easily used for both sterile and non-sterile laboratory applications. Whether your research necessitates prefiltration, sample preparation, sterile filtration, laboratory filtration, or gas venting, Nalgene syringe filters are lab essentials. Key Features. 10 to 100mL
Jan 07, 2022 · Colorimetric version of a more expensive fluorometric Syringe Enzymatic Filter Assay (SEFA). • Colorimetric SEFA utilizes DNA aptamers developed against Salmonella enterica whole cells. • Highly portable assay detects <1000 bacteria from the surface of rinsed lettuce. • Reagents can be easily dried and last at least one year at ambient
Filters are sterilized by gamma irradiation and individually packed. Filters are non-pyrogenic, RNA-free and DNA-free. Product Dimensions (dia.): 13 mm, 25 mm or 30 mm. Compatible with UltraCruz ® Syringes: sc-351868, sc-351869, sc-351870 and sc-351872. DISCOUNT: Bulk orders of Lab Supplies totaling $500 or more receive a 5% discount.
4. Remove cap from bottle and using a sterile 30 mL syringe , collect 30 mL of water. Attach the filter housing with the glass microfiber filter inside to the syringe. Hold the syringe (with the attached filter housing) over a 1000 mL beaker 5. Push the sample water through the syringe with the attached filter housing (filtration tool)
Premium PES syringe filter with PVDF syringe filters for different proteins at 0.5 mg/mL. D: Dimer, M: Monomer. Figure 3. Filtration recovery comparison of the Aijiren Captiva Premium PES syringe filter with PVDF syringe filters for myoglobin samples at different concentrations. D: Dimer, M: Monomer. 0 20 40 60 80 100 120
Use these all-plastic disposable syringes with your Titan3, Target2, and Choice Basic syringe filters. Comprising a polypropylene barrel and polyethylene plunger, these syringes eliminate problems with rubber or synthetic plunger gaskets and requires no silicone or oil lubricant in the barrel. Choose from in 1, 3, 5, 10, 20, 30, and 50 mL sizes.
Water and acetonitrile were passed through polypropylene or PTFE syringe filters (as indicated in legend), then used 1:1 (v/v) to prepare the mobile phase for UHPLC. The system was run at 0.25 mL/min for 600 min with backpressure recorded every 50 min. DP represents total change in backpressure after 600 min.
A syringe filter (or wheel filter) is a single-use, membrane-based device used for the removal of particulate impurities from small (≤ 100 mL) liquid samples ( Figure 1 ). Selected based upon the desired end application, disposable syringe filters are commonly used in labs for fast and efficient filtering, material purification, or even
Introduction. MS ® PVDF syringe filters are purpose-built with features designed to bring the highest levels of performance and purity to your research. We incorporate a variety of membranes to offer separation and purification solutions for the majority of your laboratory needs. PVDF (Polyvinylidene fluoride) – extremely low protein-binding
Syringe filters are disposable devices that are equipped with filter paper. These filter papers are available in different pore sizes, ranging from 0.2 µm – 0.45 µm. These filter devices are used to remove particular materials from the solution.
No matter your sample type, Tisch Scientific carries a wide variety of syringe filters for DNA extraction. Clean extraction of DNA can be accomplished with many of our syringe filters and devices. Whether your sample requires the application of MCE, Cellulose Acetate, PES, PTFE, Cellulose Nitrate, or Track-Etched Polycarbonate Syringe Filters, we offer a range of quality products.
Tisch Scientific Glass Fiber Syringe Filters, 0.45 μm, 13 mm Specialized glass membranes are used for DNA recovery and clean-up. Tisch Product Code: SF18312:
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack