Filters are molded in the polypropylene housings, providing a reliable seal without the use of adhesives Female luer-lock inlet and male luer slip outlet Color coded by membrane type for easy identification, and membrane material and pore size are printed on the housing Available individually packed in peel-to-open paper/plastic blister packs Also available bulk packed in PVDF, PES, PTFE, and
Feb 17, 2020 · Note: The individually packed sterile syringe filter can be held in the original package to minimize contamination while attaching the syringe. Step 3: Secure the Syringe Filter. Secure the syringe filter using a clockwise motion with luer-lock syringe. DO NOT overtighten. Step 4: Filter the Solution. Hold the assembled syringe and filter it upright.
Syringe filters are single use, self contained, filtration devices that are typically used to remove contaminating particulate from liquids or gasses. When selecting the correct syringe filter for an application there are a number of factors to consider, these include: Filter and housing materials. Pore size. Effective filtration area.
Sterile filtration, clarification, and particle removal. Minisart ® NML Syringe Filters provide the optimal method for clarification and sterilization of liquids, robustly removing bacteria and particles, without any impact on product quality or loss of target molecule. Superior filter areas up to 6.2 cm 2. 0.1µm to 5µm pore sizes.
Syringe filters are single-use, membrane-based devices used for the removal of particulate impurities from liquid and gas samples prior to analysis by methods such as HPLC, ion chromatography, gas chromatography, ICP, and dissolution testing. Proper filtration of samples improves the quality and consistency of analytical results and decreases
A variety of membranes are available to meet your needs: Polyethersulfone (PES) – low protein binding and faster flow rates; surfactant-free cellulose acetate (SFCA) – lowest protein binding; polytetrafluorethylene (PTFE) – chemical resistance; regenerated cellulose (RC) – best choice for DMSO compatibility; Nylon (NY) – hydrophilic, surfactant-free, and lowest extractable. 100%
Mar 27, 2022 · The particle size determines the pore size you use. For example, use a syringe filter of 0.2-micron pore size to filter out particles larger than 0.2 microns in diameter. Another method for determining column micron size: – use 0.45 μ for microns greater than 3 μ. – use 0.22 μ for microns less than 3 μ.
CLICK HERE to download a printable copy of this chart. Home; Catalog; About Us; Filter Selection Guide; Cannabis Testing; Resources; News! Video Conference - Topics from the Bench
Use our quick, interactive syringe filter selection guide to find out what filter is best suited to your analysis. In a few clicks you can submit your recommendations and we will send you a free, personalised sample pack. While you are here you should also look at our filtration products page. With the UK’s widest range of chromatography
Hold the syringe with the filter pointing up and “top off” by pushing a few drops through the filter. Place the filter tip over the collection container and push the sample through a syringe filter by applying gentle positive pressure. To purge the syringe filter and maximize sample throughput, remove the filter from the syringe and draw air into the syringe. Then reattach the filter and push the plunger to force some of the air through the filter.
Jan 25, 2022 · These filters are available in two pore sizes – 0.22 and 0.45µm, and are available in three different syringe filter sizes – 13, 25 and 33mm. The PP filters with a 0.22µm pore size have a water flow of 23ml/min/cm 2 and a bubble point of 340kPa. The 0.45µm pore size filters have a water flow of 46ml/min/cm 2 and a bubble point of 220kPa.
If you are using a leur lock filter, make sure you have properly secured the filter into the syringe tip, with the syringe filter facing up and “top”. Push a few drops of sample through the filter, place the filter on the overturned collection container, and gently apply pressure to push the sample into the syringe filter. The same sample can be filtered repeatedly until the syringe filter is fully functional. Remove the filter from the syringe or directly replace it with a new
How to use a Syringe Filter for embryo handling. This syringe filter has a low protein binding membrane to maximize recovery of critical components. Gamma
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack