Have any questions or comments about this article? Fill out the form below and we'll get back to you as soon as possible! Your Name (required) Your Email (required)
CHROMAFIL Syringe Filters Feature: Different membrane types to meet multiple filtration applications. Low extractable, sonic welded, leak-free polypropylene housings. Fast flow geometry for minimized back pressure during filtration. Very low hold-up volumes for maximum volume recovery. Certified clean for HPLC and UPLC analysis.
Filters are molded in the polypropylene housings, providing a reliable seal without the use of adhesives Female luer-lock inlet and male luer slip outlet Color coded by membrane type for easy identification, and membrane material and pore size are printed on the housing Available individually packed in peel-to-open paper/plastic blister packs Also available bulk packed in PVDF, PES, PTFE, and
Corning® 50 mm Diameter Syringe Filters, 0.2 µm Pore PTFE Membrane, Sterile, Individually Packaged, 12/Case 1 / Pk 12 / Cs Corning® $158.98: per case: Add to cart
0.22 micron 0.45 micron syringe filters nylon Nylon PTFE PES GF glass fiber 13mm 30mm 25mm PVDF Polyvinylidene Fluoride Cellulose Acetate Filter syringe filter
PTFE Syringe Filters. PTFE syringe filters are hydrophobic and chemically resistant to all solvents, acids, and bases. PTFE does not impart any extractables to the filtrate. It's an ideal material for transducer protectors because it blocks water vapor. PTFE is ideal for filtering and de-gassing chromatography solvents.
Intro. There are so many solvents and syringe filter/membrane materials that it can be tough to remember which combinations are safe and which are corrosive. These tables show five common syringe filter materials -- Cellulose Acetate (CA), Nylon, PES, PTFE, and PVDF -- and their compatibilities with 75 common solvents.
The shaft that connects the Plunger Flange to the seal. The pressure applied through this shaft to the seal where it presses on the liquid in the barrel. The Barrel Flange is located on the Barrel of the syringe. The syringe is supported here usually by a couple of fingers, or when the syringe is fitted to a syringe pump by the syringe retainer.
An approach to exclude such components from extracts could be a syringe filter-based DNA extraction like the one described by Lee et al. [58]. The most simple way of LAMP analysis of fungi is the
Feb 17, 2020 · Step 2: Attach a syringe filter to the Syringe. Open the syringe filter package so that you can later pick the filter up easily, especially for individually packed sterile syringe filters. a. For sample volume < 10 mL. Draw a small amount of air (about 1 mL) into the syringe before loading the sample solution.
Syringe Filter Selection Guide. Use our quick, interactive syringe filter selection guide to find out what filter is best suited to your analysis. In a few clicks you can submit your recommendations and we will send you a free, personalised sample pack. While you are here you should also look at our filtration products page.
These syringe filters are recommended for "pharmaceutical" grade HPLC Sample Prep & Dissolution Testing when GLP and GMP are required. Manufactured with proprietary and various membrane types in 25mm, 13mm or 4mm polypropylene housings. These color coded, syringe filters are also made for laboratories that require consistent, high performance
Mar 05, 2017 · Download my Parts of a Syringe Diagram . Download Now. By SyringePumpPro | 2020-04-03T01:23:09-04:00 March 5th, 2017 | About the Author: SyringePumpPro.
Syringe filters can be categorized by two essential components: the membrane and housing (Figure 1). To select the correct filter, you should ensure both components are compatible with the application. Syringe filter housings are matched based on composition and format, while membranes are matched to end applications by composition, filter diameter, and pore size.
We carry syringe filters made of nylon, glass fiber, polypropylene (PP), polyethersulfone (PES), PVDF, polytetrafluoroethylene (PTFE), cellulose acetate, and more. HPLC Syringe Filters available in two sizes: 13 mm and 30 mm; Two pore sizes: 0.2 µm and 0.45 µm; Glass Fiber syringe filters available in 1.2 and 0.7 µm; Available in 7 color
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack