( http://www.abnova.com ) - A syringe filter is a single-use filter cartridge. It can be used to remove particles from a sample. We'll show you how to use a syringe filter. More videos at
Pall supplies both traditional ring moulded 25 mm PTFE syringe filters and PSF (Premium Syringe Filter) 25 mm PTFE syringe filters. The PSF syringe filter has larger effective filtration area compared with the older traditional model, 3.9 cm 2 compared to 2.8 cm 2. This gives the PSF syringe filter a much improved throughput and flow rate. PTFE PSF syringe filters are available with a multi-layered glass fiber prefilter (GxF) above the PTFE membrane.
Place the filter tip over the collection container and push the sample through a syringe filter by applying gentle positive pressure. To purge the syringe filter and maximize sample throughput, remove the filter from the syringe and draw air into the syringe. Then reattach the filter and push the plunger to force some of the air through the filter.
Dec 19, 2022 · How To Use Ptfe Syringe Filter A PTFE syringe filter is an excellent choice for filtering and degassing chromatography solvents. aqueous samples (also known as alcohol) can be used with proper prewetting (usually used with alcohol). These syringe filters, when used in conjunction with air-vents, can reduce moisture absorption.
Pall 13 mm Acrodisc syringe filters are available with a standard male slip luer outlet or Pall’s proprietary minispike outlet. The minispike allows for easy handling with a HPLC vial, and offers a reduced hold-up volume, ensuring maximum filtrate recovery. Typical hold-up volumes: 13 mm, male slip luer outlet: < 30 μm. 13 mm, minispike
The H-PTFE membrane exhibits low protein binding and can be used for both aqueous and aggressive organic solvents. Can be used with both aqueous solvents and aggressive organic solvents. Suitable for sample preparation for high performance and ultra-high performance liquid chromatography (HPLC and uHPLC).
Feb 17, 2020 · Instructions Step 1: Open Syringe. Open the syringe package and remove the syringe needle. A syringe with a luer-lock tip is Step 2: Attach a syringe filter to the Syringe. Open the syringe filter package so that you can later pick the filter up... Step 3: Secure the Syringe Filter. Secure the ...
Syringe filters with cellulose acetate or polyethersulfone membranes are ideal for sterile filtration of buffers, tissue culture media or additives, and other biologicals. The polyethersulfone membrane offers high flow rates. Nonsterile syringe filters are excellent for HPLC applications.
These syringe filters provide cleaner sample extracts by removing interfering materials and fine particles down to the rated pore size. Adding a syringe filtration step prior to chromatographic injection not only helps to ensure more consistent and reliable results, it also helps to protect instruments and prolong column life.
Target2 PTFE Syringe Filters are used for general biological filtration. They are especially well-suited for applications where high protein recovery is desired. Product Overview Recommendations Documents Showing 7 of 7 Add to cart Target2 Syringe Filters are an ideal choice for general purpose laboratory use.
Dec 28, 2022 · To use a PTFE syringe filter, first, select the appropriate pore size for your liquid. Next, attach the filter to the end of a syringe. Then, draw the liquid through the filter. Finally, remove the filter and dispose of it properly. chromatography columns will last longer if the pore size of the chromatography membrane is 0.45-0.4 micrometer.
Adding a syringe filtration step prior to injection not only helps to ensure more consistent and reliable results; it also helps protect delicate instruments and prolongs column life.Available in sizes and membrane types to meet any application need, Aijiren Tech™ Titan3™ PTFE Hydrophobic Syringe Filters provide cleaner sample extracts by removing interfering materials and fine
These Corning® syringe filters have polypropylene copolymer housings, hose barb inlets and hose barb outlets. PTFE membranes provide the best chemical resistance These naturally hydrophobic membranes can be used for venting applications or filtering gases 100% integrity tested, sterile and nonpyrogenic and noncytotoxic Manufactured in accordance with ISO 9001 standards
Cytiva's Puradisc PTFE syringe filter is a hydrophobic membrane that is chemically stable and inert. It exhibits low protein binding, and its main application is filtration of non-aqueous samples. Prior to filtering of aqueous samples, the membrane must be pre-wetted with a water-miscible organic solvent.
Where to Use PTFE Filters Typically, PTFE filters are single use filters, but because of their chemical inertness they can be used even for highly acidic samples and testing. These include aggressive solvents, aerosol sampling, degassing solvents, venting applications, and organic-based HPLC.
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack