Custom-made As You Wish. Our syringe filtration represents the easiest and fastest method for small scale, precision solution filtration prior to column chromatography. Each unit is marked to identify the pore size, like 0.22μm and 0.45μm. We cooperate with the world-class membrane filter suppliers that ensure consistent quality.
Feb 10, 2022 · Connect the syringe filter to the needle, and tighten it gently to ensure a good seal; 3. The syringe filter is divided into two types: sterilization and non-sterile. The sterilized syringe filter needs to be pretreated before use. After the filter is installed, rinse the filter system with clean water, and then filter operate after cleaning; 4.
Syringe Filter Selection Guide. Use our quick, interactive syringe filter selection guide to find out what filter is best suited to your analysis. In a few clicks you can submit your recommendations and we will send you a free, personalised sample pack. While you are here you should also look at our filtration products page.
The hypodermic syringe, also known as the hypodermic needle, is a device used by medical professionals to transfer liquids into or out of the body. It is made up of a hollow needle, which is attached to a tube and a plunger. When the plunger handle is pulled back, fluids are drawn into the tube.
If you are using a leur lock filter, make sure you have properly secured the filter into the syringe tip, with the syringe filter facing up and “top”. Push a few drops of sample through the filter, place the filter on the overturned collection container, and gently apply pressure to push the sample into the syringe filter. The same sample
A variety of membranes are available to meet your needs: Polyethersulfone (PES) – low protein binding and faster flow rates; surfactant-free cellulose acetate (SFCA) – lowest protein binding; polytetrafluorethylene (PTFE) – chemical resistance; regenerated cellulose (RC) – best choice for DMSO compatibility; Nylon (NY) – hydrophilic, surfactant-free, and lowest extractable. 100%
Properties of Syringe Filters. The properties of syringe filters made from different materials are very different. Therefore, the choice of the filter depends greatly on the chemicals used. The following table provides an overview of the most common materials (incl. abbreviations) for syringe filters, the application areas as well as the
These syringe filters are recommended for "pharmaceutical" grade HPLC Sample Prep & Dissolution Testing when GLP and GMP are required. Manufactured with proprietary and various membrane types in 25mm, 13mm or 4mm polypropylene housings. These color coded, syringe filters are also made for laboratories that require consistent, high performance
A syringe filter is a single-use filter cartridge. It is attached to the end of a syringe for use. Syringe filters may have Luer lock fittings, though not universally so. The use of a needle is optional; where desired it may be fitted to the end of the syringe filter. A syringe filter generally consists of a plastic housing with a membrane that serves as a filter. The fluid to be purified may be cleaned by drawing it up the syringe through the filter, or by forcing the unfiltered fluid through t
Polypropylene Syringe Filters. Sterlitech Polypropylene Syringe Filters are used in a wide array of analytical and research applications for the pharmaceutical, environmental, biotechnological, and agricultural industries. The design of these syringe filters allows them to perform filtration on aqueous as well as organic solvent based samples.
Jul 18, 2019 · A syringe filter generally consists of a plastic housing with a membrane which serves as a filter. The fluid to be purified may be cleaned by drawing it up the syringe through the filter, or by forcing the unfiltered fluid out, through the filter. In scientific applications, the most common sizes available are 0.2 or 0.22 µm and 0.45 µm pores.
0.22 micron 0.45 micron syringe filters nylon Nylon PTFE PES GF glass fiber 13mm 30mm 25mm PVDF Polyvinylidene Fluoride Cellulose Acetate Filter syringe filter
Dec 07, 2020 · How Do I Use a Syringe Filter? Syringe filters are made from a virgin polypropylene housing with a female luer lock inlet and a male slip luer outlet. To use syringe filters, the sample is loaded into a disposable luer syringe. The syringe is then attached to the female luer portion of the syringe filter by securely fastening with a twisting
Mar 27, 2022 · The particle size determines the pore size you use. For example, use a syringe filter of 0.2-micron pore size to filter out particles larger than 0.2 microns in diameter. Another method for determining column micron size: – use 0.45 μ for microns greater than 3 μ. – use 0.22 μ for microns less than 3 μ.
How To Use a Syringe Filter. Fill the syringe with the solution to be filtered. Fasten the filled syringe to the FLL inlet of the syringe filter with a twisting motion. With the outlet pointed upward, gradually apply pressure to the syringe plunger to initiate flow. Continue thumb pressure until all the air in the device is displaced with
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack