We carry syringe filters made of nylon, glass fiber, polypropylene (PP), polyethersulfone (PES), PVDF, polytetrafluoroethylene (PTFE), cellulose acetate, and more. HPLC Syringe Filters available in two sizes: 13 mm and 30 mm; Two pore sizes: 0.2 µm and 0.45 µm; Glass Fiber syringe filters available in 1.2 and 0.7 µm; Available in 7 color
How To Use a Syringe Filter. Fill the syringe with the solution to be filtered. Fasten the filled syringe to the FLL inlet of the syringe filter with a twisting motion. With the outlet pointed upward, gradually apply pressure to the syringe plunger to initiate flow. Continue thumb pressure until all the air in the device is displaced with
A syringe filter is a single-use filter cartridge. It is attached to the end of a syringe for use. Syringe filters may have Luer lock fittings, though not universally so. The use of a needle is optional; where desired it may be fitted to the end of the syringe filter. A syringe filter generally consists of a plastic housing with a membrane that serves as a filter. The fluid to be purified may be cleaned by drawing it up the syringe through the filter, or by forcing the unfiltered fluid through t
Syringe filters are a cost-effective way to improve the quality of HPLC analysis, improve consistency, extend column life and reduce maintenance. By removing particulates before the sample enters the column, Navigator syringe filters allow unimpeded flow. Without particulates to create obstructio
Choose a 13mm diameter barrel for 10mL samples and a 25mm barrel for 100mL samples. For inquiries and assistance, you can reach us at 1 800-878-7654 (Customer Service Line), 707-525-5788 (Local), +31 20 638 05 97 (Europe) or email Sales@CPIInternational.com.
Dec 07, 2020 · Syringe filters are made from a virgin polypropylene housing with a female luer lock inlet and a male slip luer outlet. To use syringe filters, the sample is loaded into a disposable luer syringe. The syringe is then attached to the female luer portion of the syringe filter by securely fastening with a twisting motion.
Apr 23, 2019 · Centrifugal filters are suitable for separating such as protein or nucleic acid desalting and concentration. These devices drive the liquid through the filter through centrifugal force. And syringe filters which consist of a filter element and housing assembly are used when a sample must be filtered before entering a syringe.
If you are using a leur lock filter, make sure you have properly secured the filter into the syringe tip, with the syringe filter facing up and “top”. Push a few drops of sample through the filter, place the filter on the overturned collection container, and gently apply pressure to push the sample into the syringe filter. The same sample
Our syringe filters are made with a medical grade polypropylene housing with Luer fittings and sealed using an external ring insert to maintain membrane integrity and best performance. Klarity 25mm, 13mm and 4mm syringe filters are certified for conformance to key tests including bubble point, burst pressure, filter Integrity, water flow rate
Mar 27, 2022 · The hydrophobic type of syringe filter is generally used for gas filtration. If we use hydrophilic type PTFE or PVDF, it means we need to apply it to filtration of liquids (organic solvents, strong acids, alkalis, and aqueous solutions). It is also possible to filter organic solvents using hydrophobic membranes, such as ethanol, etc.
Feb 10, 2022 · 2. Connect the syringe filter to the needle, and tighten it gently to ensure a good seal; 3. The syringe filter is divided into two types: sterilization and non-sterile. The sterilized syringe filter needs to be pretreated before use. After the filter is installed, rinse the filter system with clean water, and then filter operate after cleaning;
Syringe filters are a cost-effective way to improve the quality of HPLC analysis, improve consistency, extend column life and reduce maintenance. By removing particulates before the sample enters the column, Navigator syringe filters allow unimpeded flow. Without particulates to create obstructio
Water and acetonitrile were passed through polypropylene or PTFE syringe filters (as indicated in legend), then used 1:1 (v/v) to prepare the mobile phase for UHPLC. The system was run at 0.25 mL/min for 600 min with backpressure recorded every 50 min. DP represents total change in backpressure after 600 min.
Syringe Filter Selection Guide. Use our quick, interactive syringe filter selection guide to find out what filter is best suited to your analysis. In a few clicks you can submit your recommendations and we will send you a free, personalised sample pack. While you are here you should also look at our filtration products page.
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack