The degree of glass ampule particle contamination has been studied based on the ampule size and the opening method of glass ampules, the size of injection needles, and the use of filters (Caudron
May 22, 2020 · 4.1/5 (1,243 Views . 13 Votes) Blunt fill needles are used for draw-up of medication, reconstitution of medication and accessing IV bags. Blunt Fill Needle with filter features a 5 micron membrane that is designed to prevent large particles from being drawn into the syringe with preparing medications from ampoules. Click to see full answer.
Mar 24, 2008 · A computer microscope was used to compare the number and size of glass particles aspirated into a syringe between two needle sizes [18 gauge (G) (130 μm lumen diameter) and 21 gauge (90 μm lumen diameter)] without filters and 19G (110 μm lumen diameter) filtered needles.
May 29, 2022 · 1 : a hermetically sealed small bulbous glass vessel that is used to hold a solution for hypodermic injection. 2 : a vial resembling an ampoule. Why use a filter needle with an ampule? Additionally, filter needles prevent the inadvertent administration of small glass fragments when drawing up medications from a glass ampule. Considering that
Several methods are used to reduce the glass particle contamination associated with breaking ampoules, such as a filter needle syringe, in-line filtering of an infusion set [3,11] and time delay
Worried about broken glass particles in your glass ampoule? In today’s video I explain what filter needles are and why and when you should use them. I’ll sho
Dec 09, 2013 · Filter needle/Straw: Filter Needle- hypodermic (sharp) needle, 19 gauge (g), 1.5 inch, with a 5. micron filter (used to filter out very fine glass particles); Blunt Filter Needle- 18g, 1.5 inch, with. a 5 micron filter; Filter Straw- flexible straw for medication aspiration from ampules, 1.75 inch,
Oct 01, 2006 · The use of filter needles was recommended by Hahn (1990) and McConnell (1993) when aspirating from ampules to prevent introduction of glass particles. Filter needles, which have a screening device in the hub to remove minute particles or foreign materials from liquid solutions, are effective in removing glass particles from broken ampules
Particle contamination of medications obtained from glass ampules can pose serious hazards to patients. Particle contamination may be reduced by using a filter needle when obtaining medication from glass ampules prior to administration. The purpose of this article is 2-fold, to educate nursing staff
The Ampule breaker/collar is compatible with use for 1-4 mL ampules. This product is very easy to use. First, slip the polyethylene breaker/ collar over top of ampule. Then grip the bottom of ampule with one hand and breaker/collar with other. Gently snap top of ampule off. Lastly, discard collar and ampule top. This product is sold in a pack
Product Description. The B Braun Medical Filter Straw is a unique medical instrument comprised of needle-free assistance with USP <797> requirements, for the sterile filtration of glass ampule contents. The device has been designed to enhance patient safety by reducing potential for glass particle injection when using single-dose glass ampules.
This includes considering established guidelines and standards from pharmacy and nursing health care organizations when preparing medications from ampoules. Blunt filter needles or filter straws with a 5 micron filter should be available and used each and every time a medication is aspirated from a glass ampoule to reduce glass particle contamination Such action will promote patient safety and reduce the risk of patient harm.
Apr 22, 2003 · Using a 0.22-µm in-line filter offers little or no additional benefit, and is more costly and labor intensive--once the ampule content is aspirated into a syringe, the filter needle must be replaced with a standard needle prior to transferring or administering the medication. Based on the available information, a filter needle is recommended
5 micron particulate filter keeps particles on surface and within the body of its sponge-like structure; allos retention of smaller particles than its rating; more efficient than sieve-type filter; can trap more particles than standard surface-type filter. Blunt Filter Needle: Specifically designed to reduce the risk for needlestick injuries
Helps reduce particulates larger than 5μ when aspirating, reconstituting and transferring fluids, or when withdrawing medication from glass ampules. BD Luer-Lok™ tip and molded-in membrane filter help eliminate the possibility of filter disassembly. Clear plastic hub permits continuous inspection of fluids.
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack