CHROMAFIL disposable syringe filters are used for filtration of suspended matter from liquid samples (1–100 mL). The filter can be used for sample preparation for HPLC, GC, ICP, AAS, TOC, DOC, IR, NMR, photometry, and spectroscopy samples to filter out contaminants and extraneous particles that can affect analytical results or clog liquid pathways, frits, etc.
Syringe Filters MilliporeSigma™ Millex™-GP Sterile Syringe Filter Units with PES Membrane, 0.22 μm (Research Use Only) Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions
Filters are molded in the polypropylene housings, providing a reliable seal without the use of adhesives Female luer-lock inlet and male luer slip outlet Color coded by membrane type for easy identification, and membrane material and pore size are printed on the housing Available individually packed in peel-to-open paper/plastic blister packs Also available bulk packed in PVDF, PES, PTFE, and
High pressures can be obtained when using syringes. The smaller the syringe the higher the pressure that can be generated. As a general guide, the following pressures can be obtained by hand with the syringes indicated: 20 mL; 80 psi; 10mL, 140 psi; 5mL, 180 psi; 3mL, 200 psi; 1mL, 250 psi.
MS® CA Syringe filters are suitable for the filtration of aqueous solutions. Cellulose Acetate combine high flow rates and thermal stability with very low absorption characteristics. Especially 0.22μm pore size CA Membrane excellently suited for sterilization aqueous solutions, buffers, sera and media. PDF [ 6 Page / 1.004kb]
Syringe Filter Selection Guide. Use our quick, interactive syringe filter selection guide to find out what filter is best suited to your analysis. In a few clicks you can submit your recommendations and we will send you a free, personalised sample pack. While you are here you should also look at our filtration products page.
Intro. There are so many solvents and syringe filter/membrane materials that it can be tough to remember which combinations are safe and which are corrosive. These tables show five common syringe filter materials -- Cellulose Acetate (CA), Nylon, PES, PTFE, and PVDF -- and their compatibilities with 75 common solvents.
( http://www.abnova.com ) - A syringe filter is a single-use filter cartridge. It can be used to remove particles from a sample. We'll show you how to use a
Sterile filtration, clarification, and particle removal. Minisart ® NML Syringe Filters provide the optimal method for clarification and sterilization of liquids, robustly removing bacteria and particles, without any impact on product quality or loss of target molecule. Superior filter areas up to 6.2 cm 2. 0.1µm to 5µm pore sizes.
Syringe filters are sterilized by gamma irradiation, preventing the contamination risk that can result from ethylene oxide sterilization. They are individually blister packed to ensure sterility during storage and handling. Replacing a syringe filter midway through the process may lead to contamination, spills, and workflow disruption.
Syringe filters (or wheel filters) are a single-use filter cartridge locate at the end of a syringe. Syringe filters can have luer lock fittings for a secure fit to the syringe. Choose from our wide assortment of filters to suit your application. Syringe filters come in a variety of membrane types.
Millex® Syringe filters set the standard for reliable small volume filtration (1 mL to 200 mL). Available in 4, 13, 25, 33, and 50 mm diameters. Minimal hold-up volume for less sample loss o f small volumes and are ideal for solutions such as antibiotics and tissue culture additives. Their unsurpassed quality and consistency of results has led
Filter mindmap based on MARKERS. Remco. 8 months ago. The assignment of markers to topics is great. But, it is more powerful if you can filter with these markers. Like hiding or showing based on one or more markers assigned. For example; show all topics with the priority 1 icons assigned. 0. Please sign in to leave a comment.
Water and acetonitrile were passed through polypropylene or PTFE syringe filters (as indicated in legend), then used 1:1 (v/v) to prepare the mobile phase for UHPLC. The system was run at 0.25 mL/min for 600 min with backpressure recorded every 50 min. DP represents total change in backpressure after 600 min.
PTFE Syringe Filters. PTFE syringe filters are hydrophobic and chemically resistant to all solvents, acids, and bases. PTFE does not impart any extractables to the filtrate. It's an ideal material for transducer protectors because it blocks water vapor. PTFE is ideal for filtering and de-gassing chromatography solvents.
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack