Acrodisc® Syringe Filter - 10 µm with Versapor membrane, polypropylene housing, AutoPack tubes (25/pkg 200/cs) Product ID AP-4000 Unit of Measure 1/BOX Min Order Qty 1 Pore Size 10 µm µm nominal Diameter (Metric) 25 mm Effective Filtration Area (Metric) 3.9 cm² Filter Media Versapor® (hydrophilic acrylic copolymer on a nonwoven support)
There are 15 syringe filter materials to choose from. To help you select the proper one for your application, the following list includes the type of filter membrane material, its characteristics and compatibility with solutions. Cellulose Acetate
The material of the syringe filter is probably the most important factor when doing a cell culture. It must be compatible with the characteristics of your cell culture and the solutions in which it comes into contact. The correct filter material addresses such performance considerations as: Flow Volume capacity/throughput Clogging
Dec 27, 2016 · On a sterile syringe filter, does the filter material matter? I see nylon and other materials available but don't know which to choose. Thank you for any help
A syringe filter (or wheel filter) is a single-use, membrane-based device used for the removal of particulate impurities from small (≤ 100 mL) liquid samples (Figure 1). Selected based upon the desired end application, disposable syringe filters are commonly used in labs for fast and efficient filtering, material purification, or even sterilization.
Jul 18, 2019 · Syringe filters range in diameter from 4 mm to 50 mm. The larger the diameter, the more particles can be captured on the filter surface before it begins to block, leading to back pressure and the force that must be applied to the syringe plunger to extract the purified material. The size of the syringe filter is up to the diameter of the
Sterile filtration, clarification, and particle removal. Minisart ® NML Syringe Filters provide the optimal method for clarification and sterilization of liquids, robustly removing bacteria and particles, without any impact on product quality or loss of target molecule. Superior filter areas up to 6.2 cm 2. 0.1µm to 5µm pore sizes.
Syringe filters can have luer lock fittings for a secure fit to the syringe. Choose from our wide assortment of filters to suit your application. Syringe filt MORE + Plastic syringes — luer-slip, luer-lock and more. Disposable Syringes Syringe Membrane Material Types Nylon PTFE Hydrophilic PTFE PES PVDF Hydrophilic PVDF MCE Regenerated Cellulose
The pore size of your syringe filter is determined by the size of the particles you need to filter out of your aqueous solution. Syringe filters for aqueous solutions are available in these pore sizes: 0.05 µm, 0.10 µm, 0.22 µm, 0.45 µm, 0.70 µm, 0.80 µm, 1 µm, 3 µm, 5 µm, and 10 µm . As a guide, the finer the pore, the more pressure
Filters are molded in the polypropylene housings, providing a reliable seal without the use of adhesives Female luer-lock inlet and male luer slip outlet Color coded by membrane type for easy identification, and membrane material and pore size are printed on the housing Available individually packed in peel-to-open paper/plastic blister packs Also available bulk packed in PVDF, PES, PTFE, and
Mar 27, 2022 · Which material should you use for a syringe filter? There are many materials you can choose from. Here are some of the most common ones: Cellulose Acetate (CA) Cellulose acetate (CA) has an excellent flow rate. Yet, they have a limited protein binding capacity. Besides, a little protein is making them ideal for protein recovery applications.
Syringe Filters Products Material Classifications> Polyamide/Nylon (PA) – Hydrophilic Polytetrafluoroethylene (PTFE) – Hydrophilic or Hydrophobic Polyvinylidene difluoride (PVDF) – Hydrophobic Polyethersulfone (PES) – Hydrophilic Cellulose Acetate (CA) – Hydrophilic Mixed Cellulose Esters (MCE)-Hydrophilic Prefilters, Glass Microfiber
Advantage of syringe filter. 1. Syringe filter Nylon material: good temperature resistance, good chemical stability, resistance to various organic and inorganic compounds and solvents such as dilute acid and alkali. Natural hydrophilicity, no wetting agent is needed during use, and the filter fluid is not contaminated. 2.
The Material of Syringe Filter. Syringe filter can be used in the analysis of high performance liquid chromatography and IC. It is an important step in sample pretreatment to filter sample solution. The syringe filter with high quality is produced by using the most advanced detection means and production technology. The product quality is far superior to that of other domestic counterparts.
Feb 17, 2020 · A syringe filter (sometimes called a wheel filter for its wheel-like shape) is a single-use membrane based filter cartridge, to be attached with a syringe to remove impurities in liquid solutions. This pre-filtration step is vital in preventing damage to instruments (e.g. liquid chromatography, ICP, etc.).
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack