Sterile filtration, clarification, and particle removal. Minisart ® NML Syringe Filters provide the optimal method for clarification and sterilization of liquids, robustly removing bacteria and particles, without any impact on product quality or loss of target molecule. Superior filter areas up to 6.2 cm 2. 0.1µm to 5µm pore sizes.
Intro. There are so many solvents and syringe filter/membrane materials that it can be tough to remember which combinations are safe and which are corrosive. These tables show five common syringe filter materials -- Cellulose Acetate (CA), Nylon, PES, PTFE, and PVDF -- and their compatibilities with 75 common solvents.
Filters are molded in the polypropylene housings, providing a reliable seal without the use of adhesives Female luer-lock inlet and male luer slip outlet Color coded by membrane type for easy identification, and membrane material and pore size are printed on the housing Available individually packed in peel-to-open paper/plastic blister packs Also available bulk packed in PVDF, PES, PTFE, and
Jan 29, 2018 · You can hold the extension directly under the faucet or use a 60 mL syringe to push hot soapy water through it. After washing, close the clamp and drag it down the extension to “strip” the extension of its residue. You can also use the back of a butter knife, as if you were curling ribbon, to loosen residue.
Feb 17, 2020 · It is possible for an extended sampling range using hydrophobic PTFE filters for wider chemical resistance to aggressive substances and outstanding temperature stability. A PTFE syringe filter is an ideal choice for filtering and de-gassing chromatography solvents.
Syringe Filters MilliporeSigma™ Millex™-GP Sterile Syringe Filter Units with PES Membrane, 0.22 μm (Research Use Only) Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions
PTFE Syringe Filters. PTFE syringe filters are hydrophobic and chemically resistant to all solvents, acids, and bases. PTFE does not impart any extractables to the filtrate. It's an ideal material for transducer protectors because it blocks water vapor. PTFE is ideal for filtering and de-gassing chromatography solvents.
Add to Cart. Whatman 6888-2527 GD/X 25 mm Syringe Filter, glass microfiber GF/D filtration medium, 2.7 um (150 pcs) Regular Price $539.90 Price $468.86. Add to Cart. Whatman Puradisc FP 30 mm Cellulose Acetate Syringe Filter, 1.2 µm, Sterile, 50 Pack, 10462261. Regular Price $114.27 Price $99.24.
A. Microbore Extension Set. Peel pouch or soft blister. 100. 580mm*220mm*320mm. B. UV protected Microbore Extension Set. Peel pouch or soft blister. 100.
No matter your sample type, Tisch Scientific carries a wide variety of syringe filters for DNA extraction. Clean extraction of DNA can be accomplished with many of our syringe filters and devices. Whether your sample requires the application of MCE, Cellulose Acetate, PES, PTFE, Cellulose Nitrate, or Track-Etched Polycarbonate Syringe Filters
Syringe filters are sterilized by gamma irradiation, preventing the contamination risk that can result from ethylene oxide sterilization. They are individually blister packed to ensure sterility during storage and handling. Replacing a syringe filter midway through the process may lead to contamination, spills, and workflow disruption.
Sep 25, 2014 · FS116. Mini-Vol™ Extension Set with 0.2 Micron Filter, Non-Removable Slide Clamp, Male Luer Lock. Non-DEHP Formulation Fluid Path, Latex-Free. 0.7 mL. 62" (157 cm) 25. FS117. Micro Bore Extension with 0.2 Micron Filter, Non-Removable Blue Slide Clamp, "Y" Injection Site,Male Luer Lock. Non-DEHP Formulation Fluid Path, Latex-Free.
Can Syringe Filters be Reused. Multi-process mold extensions for inclusion of single or multi-level prefiltration media. Digital variable print capabilities along an arc on barrel face for identification purposes. Blister packing for EO and gamma sterilization. Pure virgin PP, verified by HPLC against U/L extractable. Payment: 100% T/T in advance.
Hold the syringe with the filter pointing up and “top off” by pushing a few drops through the filter. Place the filter tip over the collection container and push the sample through a syringe filter by applying gentle positive pressure. To purge the syringe filter and maximize sample throughput, remove the filter from the syringe and draw air into the syringe. Then reattach the filter and push the plunger to force some of the air through the filter.
Polypropylene Syringe Filters. Sterlitech Polypropylene Syringe Filters are used in a wide array of analytical and research applications for the pharmaceutical, environmental, biotechnological, and agricultural industries. The design of these syringe filters allows them to perform filtration on aqueous as well as organic solvent based samples.
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack