Sterile filtration, clarification, and particle removal. Minisart ® NML Syringe Filters provide the optimal method for clarification and sterilization of liquids, robustly removing bacteria and particles, without any impact on product quality or loss of target molecule. Superior filter areas up to 6.2 cm 2. 0.1µm to 5µm pore sizes.
A syringe filter (sometimes called a wheel filter if it has a wheel-like shape) is a single-use filter cartridge. It is attached to the end of a syringe for use. Syringe filters may have Luer lock fittings, though not universally so. The use of a needle is optional; where desired it may be fitted to the end of the syringe filter.
Jun 21, 2017 · The Wide Application of PVDF Filters: The sterilization of protein-containing solutions, media preservatives, and antibiotics can be best done using a PVDF filter. They are compatible with most of HPLC samples and aggressive chemicals. These filters are designed with an internal pre-filter and PP housing having an outer colored ring.
Oct 29, 2019 · Syringe filtration is a great, fast method of filtering samples prior to further analysis by HPLC and UV-VIS analysis or other analytical techniques. Some samples which have a high amount of solid particulates in them and can block up syringe filters and which slow down the process.
Feb 17, 2020 · These syringe filters offer outstanding microfiltration for applications in HPLC, water treatment, environmental, biotechnology, beverages, food, pharmaceuticals, and other fields related. The key differences are chemical compatibility, flow rate, and burst pressure (i.e. strength).
Mar 27, 2018 · Syringe filter is a one-time usage cartridge. It basically designed to attach the end of a syringe to use, syringe filters have a Luer locking system to fit perfectly with the syringe. This fitting system may vary universally. The usage of the needle is purely optional, based on the requirement it can fix with Syringe which is having Assurance
Regardless of the application, the potential of encountering such problems can be significantly reduced by utilizing the best HPLC syringe filters for the job. We carry syringe filters made of nylon, glass fiber, polypropylene (PP), polyethersulfone (PES), PVDF, polytetrafluoroethylene (PTFE), cellulose acetate, and more.
Mar 27, 2022 · Use a non-sterilized syringe filter for routine filtering and sample purification. You can use non-sterile syringe filters for: Pre-filtration; General filtration; Analytical sample preparation applications; How to Use a Syringe Filter? Step-by-Step Guide 1. Fill the syringe with the sample. 2. Using a twisting motion, secure the filter.
Application. Syringe filters may be used to remove particles from a sample, prior to analysis by HPLC. Particles easily damage an HPLC due to the narrow bore and high pressures within. Syringe filters are quite suitable for Schlenk line work, which makes extensive use of needles and syringes.
Syringe Filters for Medical Applications MMF syringe filters are an ideal choice for filtration of anesthesia, biosensor protecting system. They can provide excellent barrier for sterile venting of bench top instruments, or protecting vacuum pumps from damage by aqueous solutions or moisture.
A syringe filter (or wheel filter) is a single-use, membrane-based device used for the removal of particulate impurities from small (≤ 100 mL) liquid samples (Figure 1). Selected based upon the desired end application, disposable syringe filters are commonly used in labs for fast and efficient filtering, material purification, or even sterilization.
Sep 07, 2020 · 33mm diameter – for samples <250ml. 4. Select syringe fitting. Most syringe filters with come with the standardised Luer fitting – either Luer Lock or Luer Slip. Luer Slip – will fit on to any Luer fitting syringe. Simply ‘slip’ the filter onto the end of your syringe. It is quick to add and remove from the syringe.
Regenerated Cellulose syringe filters are used for low nonspecific binding applications, as well as tissue culture media filtration and general biological sample filtration. They have strong resistance to standard aqueous and organic HPLC solvents such as acetonitrile or methanol and so recommended for UHPLC / HPLC sample preparation and DMSO
Feb 10, 2022 · 1. The syringe filter has different membrane materials, and the different membranes materials have different applications. The filter membrane is suitable for sample filtration should be selected according to the your experimental needs; 2. Connect the syringe filter to the needle, and tighten it gently to ensure a good seal; 3. The syringe
Filtration is a critical part of analytical sample prep, yet choosing the right syringe filter for your specific application can be challenging. Register to learn how to simplify the process. What we’ll cover: Why correct membrane selection is important for optimal instrument protection and the most accurate results.
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack