Best Sellers in Syringe Lab Filters #1 10 Pack Syringe Filter Sterile PES Hydrophilic Filtration 0.22um Pore Size, 33mm Membrane Diameter Sterile PES Membrane Individually Packed by Membrane Solutions 474 3 offers from $13.99 #2 Biomed Scientific Syringe Filters PTFE 13mm Diameter 0.22um Pore Size Non Sterile Pack of 10 214 7 offers from $8.99 #3
We carry syringe filters made of nylon, glass fiber, polypropylene (PP), polyethersulfone (PES), PVDF, polytetrafluoroethylene (PTFE), cellulose acetate, and more. HPLC Syringe Filters available in two sizes: 13 mm and 30 mm; Two pore sizes: 0.2 µm and 0.45 µm; Glass Fiber syringe filters available in 1.2 and 0.7 µm; Available in 7 color
Jul 18, 2019 · Syringe Filter Size. Syringe filters range in diameter from 4 mm to 50 mm. The larger the diameter, the more particles can be captured on the filter surface before it begins to block, leading to back pressure and the force that must be applied to the syringe plunger to extract the purified material.
A variety of membranes are available to meet your needs: Polyethersulfone (PES) – low protein binding and faster flow rates; surfactant-free cellulose acetate (SFCA) – lowest protein binding; polytetrafluorethylene (PTFE) – chemical resistance; regenerated cellulose (RC) – best choice for DMSO compatibility; Nylon (NY) – hydrophilic, surfactant-free, and lowest extractable. 100%
A syringe filter (or wheel filter) is a single-use, membrane-based device used for the removal of particulate impurities from small (≤ 100 mL) liquid samples ( Figure 1 ). Selected based upon the desired end application, disposable syringe filters are commonly used in labs for fast and efficient filtering, material purification, or even
EZFlow 13mm, 25mm, and 33mm Syringe Filters are used for prefiltration, clarification, or fine particulate removal. These syringe filters are available in a variety of filter membrane materials, offered in 0.2µm or 0.45µm pore sizes. The filter membranes are reinforced with polypropylene
Jun 11, 2020 · The Best Quality Syringe Filters for Laboratory Process - simsiinetinc’s diary A Sterile syringe filter is the most demanding and best choice for filtering product quality and aqueous solutions. Syringe filters are the creation of purpose to bring the research performance and purity to the peak level.
Filters are molded in the polypropylene housings, providing a reliable seal without the use of adhesives Female luer-lock inlet and male luer slip outlet Color coded by membrane type for easy identification, and membrane material and pore size are printed on the housing Available individually packed in peel-to-open paper/plastic blister packs Also available bulk packed in PVDF, PES, PTFE, and
Sep 22, 2011 · I know several people prefer .2 micron and several prefer .45 micron filters, which I understand for bacteria/viruses. Nobody ever mentions which subtype they use with the greatest success though. Such as: (all whatman types) ANOTOP. GD/X. GD/XP. PURADISC.
Feb 20, 2020 · Syringe Filter is commonly used to expel particles from a liquid sample preceding an examination to keep away from harm to equipment. Simsii has a full range of Syringe filters. For more information about this product, visit our site simsii.net and you can call us today at 1-949-336-8212
Syringe Filter Selection Guide. Use our quick, interactive syringe filter selection guide to find out what filter is best suited to your analysis. In a few clicks you can submit your recommendations and we will send you a free, personalised sample pack. While you are here you should also look at our filtration products page.
These syringe filters are recommended for "pharmaceutical" grade HPLC Sample Prep & Dissolution Testing when GLP and GMP are required. Manufactured with proprietary and various membrane types in 25mm, 13mm or 4mm polypropylene housings. These color coded, syringe filters are also made for laboratories that require consistent, high performance
Dec 07, 2020 · The main selection criteria for your syringe filter membrane is solvent compatibility and application (specifically, if you are concerned with protein binding). Nylon membranes are used for general laboratory filtration of HPLC samples prior to injection. Nylon is solvent resistant, exhibits lows extractables, and is compatible with both
PTFE Syringe Filters. PTFE syringe filters are hydrophobic and chemically resistant to all solvents, acids, and bases. PTFE does not impart any extractables to the filtrate. It's an ideal material for transducer protectors because it blocks water vapor. PTFE is ideal for filtering and de-gassing chromatography solvents.
3. Biomed Scientific Syringe Filters PTFE 13mm Diameter 0.22um Pore Size Non Sterile Pack of 10. Features : Syringe Filters PTFE:Hydrophobic PTFE membrane with Polypropylene (PP) housing,non sterile. Diameter:13mm,pore size:0.22um,10/pack. Connectors:Inlet:Female luer,Outlet:male slip luer.
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack