Syringe Filter Selection Guide. Use our quick, interactive syringe filter selection guide to find out what filter is best suited to your analysis. In a few clicks you can submit your recommendations and we will send you a free, personalised sample pack. While you are here you should also look at our filtration products page.
These syringe filters are available with many different membranes, in both sterile and non-sterile varieties, and with or without pre-filters. You can also find expired sterile syringe filters at discount prices in our Clearance Section. *NOTE: Due to high demand, 13 and 25 mm diameter syringe filters are experiencing increased lead times
Jul 18, 2019 · Syringe Filter Size. Syringe filters range in diameter from 4 mm to 50 mm. The larger the diameter, the more particles can be captured on the filter surface before it begins to block, leading to back pressure and the force that must be applied to the syringe plunger to extract the purified material.
Regardless of the application, the potential of encountering such problems can be significantly reduced by utilizing the best HPLC syringe filters for the job. We carry syringe filters made of nylon, glass fiber, polypropylene (PP), polyethersulfone (PES), PVDF, polytetrafluoroethylene (PTFE), cellulose acetate, and more. HPLC Syringe Filters available in two sizes: 13 mm and 30 mm; Two pore sizes: 0.2 µm and 0.45 µm; Glass Fiber syringe filters available in 1.2 and 0.7 µm
Syringe filters (or wheel filters) are a single-use filter cartridge locate at the end of a syringe. Syringe filters can have luer lock fittings for a secure fit to the syringe. Choose from our wide assortment of filters to suit your application. Syringe filters come in a variety of membrane types. When selecting a syringe filter, be
Mar 27, 2022 · Step – Now, Select a Proper Pore Size. For research and medical purposes, 0.2/0.22 μ and 0.45 μ syringe filters are the most often used pore sizes. The particle size determines the pore size you use. For example, use a syringe filter of 0.2-micron pore size to filter out particles larger than 0.2 microns in diameter.
Dec 07, 2020 · The main selection criteria for your syringe filter membrane is solvent compatibility and application (specifically, if you are concerned with protein binding). Nylon membranes are used for general laboratory filtration of HPLC samples prior to injection. Nylon is solvent resistant, exhibits lows extractables, and is compatible with both
Water and acetonitrile were passed through polypropylene or PTFE syringe filters (as indicated in legend), then used 1:1 (v/v) to prepare the mobile phase for UHPLC. The system was run at 0.25 mL/min for 600 min with backpressure recorded every 50 min. DP represents total change in backpressure after 600 min.
Sep 07, 2020 · 33mm diameter – for samples <250ml. 4. Select syringe fitting. Most syringe filters with come with the standardised Luer fitting – either Luer Lock or Luer Slip. Luer Slip – will fit on to any Luer fitting syringe. Simply ‘slip’ the filter onto the end of your syringe. It is quick to add and remove from the syringe.
Filters are molded in the polypropylene housings, providing a reliable seal without the use of adhesives Female luer-lock inlet and male luer slip outlet Color coded by membrane type for easy identification, and membrane material and pore size are printed on the housing Available individually packed in peel-to-open paper/plastic blister packs Also available bulk packed in PVDF, PES, PTFE, and
Price PTFE Syringe Filter for Sample Preparation Turkey 33mm syringe filter, 33mm syringe filter Suppliers and Disposable 33mm 0.22 0.45um micron PES Polysulfone for sample preparation bacteria remove lab use Sterile Syringe Filter US $46.00-$92.00 / Box 2 Boxes (Min. Order) Send Inquiry. Get Price.
Feb 17, 2020 · PVDF Hydrophilic Syringe Filters 0.22um or 0.45um Hydrophilic PVDF (Polyvinylidene Fluoride) is an optimal choice for protein-based samples with high non-specific binding, HPLC (High Performance Liquid Chromatography) and UHPLC (Ultra HPLC).
Syringe filters with different pore size ratings are suitable for different applications. For example, syringe filters containing 0.45 μm are typically used for HPLC sample preparation and 0.2 μm is used for UHPLC. In life science applications 0.1 and 0.2 µm pore sizes provide sterilization of buffers, culture media, and additives.
A syringe filter (or wheel filter) is a single-use, membrane-based device used for the removal of particulate impurities from small (≤ 100 mL) liquid samples ( Figure 1 ). Selected based upon the desired end application, disposable syringe filters are commonly used in labs for fast and efficient filtering, material purification, or even
Minisart ® NML Syringe Filters provide the optimal method for clarification and sterilization of liquids, robustly removing bacteria and particles, without any impact on product quality or loss of target molecule. Superior filter areas up to 6.2 cm 2. 0.1µm to 5µm pore sizes. Low adsorption characteristics.
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack