Minisart ® NML Syringe Filters . Sterile filtration, clarification, and particle removal. Minisart ® NML Syringe Filters provide the optimal method for clarification and sterilization of liquids, robustly removing bacteria and particles, without any impact on product quality or loss of target molecule. Superior filter areas up to 6.2 cm 2.
Jan 25, 2022 · These filters are available in two pore sizes – 0.22 and 0.45µm, and are available in three different syringe filter sizes – 13, 25 and 33mm. The PP filters with a 0.22µm pore size have a water flow of 23ml/min/cm 2 and a bubble point of 340kPa. The 0.45µm pore size filters have a water flow of 46ml/min/cm 2 and a bubble point of 220kPa.
Mar 27, 2022 · Step – Now, Select a Proper Pore Size. For research and medical purposes, 0.2/0.22 μ and 0.45 μ syringe filters are the most often used pore sizes. The particle size determines the pore size you use. For example, use a syringe filter of 0.2-micron pore size to filter out particles larger than 0.2 microns in diameter.
The PES syringe filters with GF pre-filter has excellent dirt-holding capacity, which makes a syringe filter a much larger throughput for some “hard to filter” sample. UNIFORM PORE SIZE – Sterile PES Syringe Filter with uniform pore size structure; wide pore size selection, retention of granule cell collection.
12-4447 13 mm and 25mm GD/X Nylon Syringe Filters, Disposable, Cytiva Whatman. View Details. 12-4445-TS 13mm and 25mm Cellulose Acetate GD/X Syringe Filters, Disposable, Cytiva Whatman. View Details. 12-4448-TS 13mm and 25mm Polypropylene GD/X, Syringe Filters, Disposable, Cytiva Whatman. View Details.
Best Sellers in Syringe Lab Filters #1 10 Pack Syringe Filter Sterile PES Hydrophilic Filtration 0.22um Pore Size, 33mm Membrane Diameter Sterile PES Membrane Individually Packed by Membrane Solutions 474 3 offers from $13.99 #2 Biomed Scientific Syringe Filters PTFE 13mm Diameter 0.22um Pore Size Non Sterile Pack of 10 214 7 offers from $8.99 #3
[Sterile Syringe Filters]: Sterile syringe filters are made with Hydrophobic PTFE membrane with polypropylene (PP) housing,Diameter: 13mm, Pore Size: 0.22μm [Hydrophobic PTFE Advantage]:Hydrophobic PTFE membrane could resistant to almost all the organic solutions. (PH:1-14) ,also the Air/ Gas filtration.
【Size Detail】–syringe filters have a diameter of about 0.71 inch/18 mm, a length of 0.83 inch/21 mm, a hole: 0.08 inch/2 mm, and an inner diameter of 0.16 inch/4 mm. 【Wide Application】–Syringe filters are suitable for filtering small-volume samples in scientific laboratories, and you can use them when preparing samples in the
Filters are molded in the polypropylene housings, providing a reliable seal without the use of adhesives Female luer-lock inlet and male luer slip outlet Color coded by membrane type for easy identification, and membrane material and pore size are printed on the housing Available individually packed in peel-to-open paper/plastic blister packs Also available bulk packed in PVDF, PES, PTFE, and
The PSF syringe filter has a much larger effective filtration area compared with the older traditional model, 3.9 cm 2 compared to 2.8 cm 2. Therefore, this gives the PSF syringe filter a much improved throughput and flow rate.
Feb 17, 2020 · PVDF Hydrophilic Syringe Filters 0.22um or 0.45um . Hydrophilic PVDF (Polyvinylidene Fluoride) is an optimal choice for protein-based samples with high non-specific binding, HPLC (High Performance Liquid Chromatography) and UHPLC (Ultra HPLC).
Whatman ® Puradisc ® syringe filters combine premium quality and economy and are ideal for quick, efficient filtration of samples up to 100 mL volumes. Whatman ® Puradisc ® Aqua syringe filters are specifically designed for filtration of environmental samples prior to COD and DOC analysis. The membranes used in these devices are prewashed prior to assembly to reduce the organic carbon level.
Syringe Filter Selection Guide. Skip to Content. 01357 522 961. Quick Order.
Choosing the proper filter size is crucial to avoid rupturing the syringe filter’s housing. As a guide, if the volume of fluid to filter is: 5 to 1.0 ml, then use a 4mm syringe filter; 2-10 ml, then use a 13mm syringe filter; 10-100 ml (or up to 200 ml with a prefilter), then use a 25mm syringe filter; 2-5 L, then use a 50mm syringe filter.
Syringe Filter Selection Guide - Crawford ScientificSyringe Filter Selection Guide. Use our quick, interactive syringe filter selection guide to find out what filter is best suite Tel: 8618057059123
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 8mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 9mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 10mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Volume: 2ml (standard volume) 1.5ml(actual volume)
Application: HPLC and GC system
Dimensions: 11.6 x 32mm
Neck Diameter: 11mm
Qty/Pack: 100pcs/pack
Payment: T/T
MOQ: 1pack